CVE-2026-1632
📋 TL;DR
MOMA Seismic Station versions v2.4.2520 and earlier expose their web management interface without requiring authentication. This allows unauthenticated attackers to modify device configurations, access sensitive data, or perform remote resets. Organizations using these vulnerable seismic monitoring devices are affected.
💻 Affected Systems
- MOMA Seismic Station
⚠️ Manual Verification Required
This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.
Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).
🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.
- Review the CVE details at NVD
- Check vendor security advisories for your specific version
- Test if the vulnerability is exploitable in your environment
- Consider updating to the latest version as a precaution
⚠️ Risk & Real-World Impact
Worst Case
An attacker could reconfigure seismic monitoring parameters to suppress alerts, access sensitive geological data, or disable the device entirely, potentially compromising safety monitoring systems.
Likely Case
Unauthenticated attackers accessing the web interface to view device data, modify basic settings, or perform device resets disrupting monitoring operations.
If Mitigated
With proper network segmentation and access controls, impact is limited to internal network compromise rather than direct device manipulation.
🎯 Exploit Status
Exploitation requires only web browser access to the management interface. No special tools or techniques needed.
🛠️ Fix & Mitigation
✅ Official Fix
Patch Version: v2.4.2521 or later
Vendor Advisory: https://www.cisa.gov/news-events/ics-advisories/icsa-26-034-03
Restart Required: Yes
Instructions:
1. Download updated firmware from vendor. 2. Backup current configuration. 3. Apply firmware update via web interface. 4. Verify authentication is now required. 5. Restart device.
🔧 Temporary Workarounds
Network Segmentation
allIsolate MOMA Seismic Station devices on separate VLAN with strict firewall rules
Access Control Lists
linuxImplement IP-based restrictions to only allow authorized management stations
# Example firewall rule (adjust for your environment)
iptables -A INPUT -p tcp --dport 80 -s 192.168.1.0/24 -j ACCEPT
iptables -A INPUT -p tcp --dport 80 -j DROP
🧯 If You Can't Patch
- Implement strict network segmentation to isolate devices from untrusted networks
- Deploy network-based authentication proxy in front of the web interface
🔍 How to Verify
Check if Vulnerable:
Attempt to access the web management interface (typically port 80/443) without credentials. If you can access configuration pages without login, the device is vulnerable.
Check Version:
Check web interface footer or about page, or use: curl -s http://device-ip/ | grep -i version
Verify Fix Applied:
After patching, attempt to access web interface without credentials. You should be redirected to a login page or receive authentication error.
📡 Detection & Monitoring
Log Indicators:
- Unauthenticated access to admin pages
- Configuration changes from unexpected IPs
- Multiple failed login attempts followed by successful access
Network Indicators:
- HTTP requests to /admin, /config, or /settings paths without authentication headers
- Traffic to seismic station on port 80/443 from unexpected sources
SIEM Query:
source="moma_logs" AND (url_path="/admin" OR url_path="/config" OR url_path="/settings") AND NOT (http_auth="*" OR cookie="session*")