CVE-2025-58083

10.0 CRITICAL

📋 TL;DR

The General Industrial Controls Lynx+ Gateway has a critical authentication bypass vulnerability in its embedded web server that allows unauthenticated attackers to remotely reset the device. This affects all organizations using this industrial control system gateway. The vulnerability stems from missing authentication mechanisms for critical functions.

💻 Affected Systems

Products:
  • General Industrial Controls Lynx+ Gateway
Versions: All versions prior to patched version
Operating Systems: Embedded OS on Lynx+ Gateway
Default Config Vulnerable: ⚠️ Yes
Notes: All deployments are vulnerable in default configuration. No special configuration required for exploitation.

⚠️ Manual Verification Required

This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.

Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).

🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.

Recommended Actions:
  1. Review the CVE details at NVD
  2. Check vendor security advisories for your specific version
  3. Test if the vulnerability is exploitable in your environment
  4. Consider updating to the latest version as a precaution

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete disruption of industrial operations through device reset, potentially causing production downtime, safety system failures, or process control interruptions in critical infrastructure.

🟠

Likely Case

Unauthorized device reset leading to temporary service disruption, configuration loss, and potential manipulation of industrial control processes.

🟢

If Mitigated

Limited impact if device is isolated behind multiple security layers with strict network segmentation and monitoring.

🌐 Internet-Facing: HIGH - Direct internet exposure makes exploitation trivial and could lead to immediate operational impact.
🏢 Internal Only: HIGH - Even internally, the lack of authentication allows any network-connected attacker to exploit this vulnerability.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: LIKELY
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Exploitation requires only network access to the device's web interface. No authentication or special tools needed.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Check vendor advisory for specific patched version

Vendor Advisory: https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08

Restart Required: Yes

Instructions:

1. Review CISA advisory ICSA-25-317-08
2. Contact General Industrial Controls for patch availability
3. Schedule maintenance window for update
4. Apply firmware update following vendor instructions
5. Restart device to activate patch
6. Verify authentication is now required for reset function

🔧 Temporary Workarounds

Network Segmentation

all

Isolate Lynx+ Gateway from untrusted networks using firewalls and VLANs

Access Control Lists

all

Implement strict network ACLs to limit access to gateway management interface

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate device from all untrusted networks
  • Deploy industrial firewall with deep packet inspection to block unauthorized reset attempts

🔍 How to Verify

Check if Vulnerable:

Attempt to access device reset function via web interface without authentication. If reset is possible without credentials, device is vulnerable.

Check Version:

Check device web interface for firmware version or use vendor-specific CLI commands if available

Verify Fix Applied:

After patching, attempt to access reset function without authentication. Should receive authentication prompt or access denied.

📡 Detection & Monitoring

Log Indicators:

  • Unauthenticated access to reset endpoints in web server logs
  • Device reboot events without authorized user activity
  • Failed authentication attempts followed by successful reset

Network Indicators:

  • HTTP requests to reset endpoints without authentication headers
  • Unusual traffic patterns to industrial control gateway management interface

SIEM Query:

source="lynx_gateway" AND (uri="/reset" OR uri="/admin/reset") AND NOT auth_successful=true

🔗 References

📤 Share & Export