CVE-2024-48217

8.8 HIGH

📋 TL;DR

This CVE describes an Insecure Direct Object Reference (IDOR) vulnerability in SiSMART v7.4.0 dashboard that allows attackers to access other users' data or perform unauthorized actions. Attackers can execute horizontal privilege escalation by manipulating object references. Organizations using SiSMART v7.4.0 are affected.

💻 Affected Systems

Products:
  • SiSMART
Versions: v7.4.0
Operating Systems: All platforms running SiSMART
Default Config Vulnerable: ⚠️ Yes
Notes: Only affects the dashboard component of SiSMART v7.4.0

⚠️ Manual Verification Required

This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.

Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).

🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.

Recommended Actions:
  1. Review the CVE details at NVD
  2. Check vendor security advisories for your specific version
  3. Test if the vulnerability is exploitable in your environment
  4. Consider updating to the latest version as a precaution

⚠️ Risk & Real-World Impact

🔴

Worst Case

Attackers could access sensitive data of all users, modify configurations, or perform unauthorized administrative actions leading to data breach or system compromise.

🟠

Likely Case

Attackers access other users' dashboard data, view sensitive information, or perform unauthorized actions within the same privilege level.

🟢

If Mitigated

Limited to accessing only the attacker's own data with proper access controls and validation.

🌐 Internet-Facing: HIGH
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ⚠️ Yes
Weaponized: LIKELY
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploitation requires authenticated access but is straightforward once authenticated

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Unknown

Vendor Advisory: Unknown

Restart Required: No

Instructions:

No official patch available. Monitor vendor for updates and apply when released.

🔧 Temporary Workarounds

Implement proper access controls

all

Add server-side authorization checks for all object references

Use indirect reference maps

all

Replace direct object references with indirect references that are validated server-side

🧯 If You Can't Patch

  • Implement web application firewall (WAF) rules to detect and block IDOR patterns
  • Restrict network access to SiSMART dashboard to trusted IPs only

🔍 How to Verify

Check if Vulnerable:

Test if authenticated users can access other users' data by manipulating object IDs in dashboard requests

Check Version:

Check SiSMART version in dashboard interface or configuration files

Verify Fix Applied:

Verify that server-side authorization checks prevent access to unauthorized objects

📡 Detection & Monitoring

Log Indicators:

  • Multiple failed authorization attempts
  • Access to user IDs outside normal range
  • Unusual access patterns to dashboard endpoints

Network Indicators:

  • Repeated requests with sequential object IDs
  • Requests to dashboard endpoints with modified parameters

SIEM Query:

source="sismart" AND (event_type="authorization_failure" OR (url_path="/dashboard/*" AND parameter_modification=true))

🔗 References

📤 Share & Export