CVE-2024-46892

4.9 MEDIUM

📋 TL;DR

This vulnerability allows authenticated attackers to maintain active sessions even after their user accounts have been disabled or deleted in SINEC INS. Attackers could continue performing malicious actions with their old permissions. All SINEC INS users with versions before V1.0 SP2 Update 3 are affected.

💻 Affected Systems

Products:
  • SINEC INS
Versions: All versions < V1.0 SP2 Update 3
Operating Systems: Not specified - application-level vulnerability
Default Config Vulnerable: ⚠️ Yes
Notes: This affects the SINEC Industrial Network Server software used in industrial automation environments.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

A malicious insider or compromised account could maintain persistent access to critical industrial control systems even after being detected and disabled, potentially causing operational disruption or data exfiltration.

🟠

Likely Case

Former employees or contractors with disabled accounts could maintain unauthorized access to SINEC INS systems, potentially accessing sensitive industrial network data or configurations.

🟢

If Mitigated

With proper session management controls and monitoring, the impact is limited to temporary persistence until sessions naturally expire.

🌐 Internet-Facing: MEDIUM
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploitation requires an authenticated session and knowledge that the account will be disabled. Attackers could intentionally trigger this by getting their account disabled while maintaining active sessions.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: V1.0 SP2 Update 3

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-915275.html

Restart Required: Yes

Instructions:

1. Download V1.0 SP2 Update 3 from Siemens support portal. 2. Backup current configuration. 3. Apply the update following Siemens installation guide. 4. Restart the SINEC INS application/service. 5. Verify all sessions are properly invalidated after user changes.

🔧 Temporary Workarounds

Manual Session Termination

all

Manually terminate all active sessions after disabling or modifying user accounts

Not applicable - requires administrative action in SINEC INS interface

Reduce Session Timeout

all

Configure shorter session timeout values to limit persistence window

Configure in SINEC INS administration interface under session settings

🧯 If You Can't Patch

  • Implement strict monitoring of user account changes and immediately force-logout all sessions for disabled/modified users
  • Deploy network segmentation to limit SINEC INS access to only necessary personnel and systems

🔍 How to Verify

Check if Vulnerable:

Check SINEC INS version in administration interface. If version is earlier than V1.0 SP2 Update 3, system is vulnerable.

Check Version:

Check version in SINEC INS web interface under System Information or Administration panel

Verify Fix Applied:

After patching: 1. Create test user. 2. Login with test user. 3. Disable test user account. 4. Verify test user session is immediately terminated and cannot perform actions.

📡 Detection & Monitoring

Log Indicators:

  • User account disabled/modified but same user continues to generate activity logs
  • Session persistence after user status changes
  • Failed logout events for disabled users

Network Indicators:

  • Continued network traffic from disabled user accounts
  • Authentication attempts from sessions that should be invalid

SIEM Query:

source="sinec_ins" AND (user_status="disabled" OR user_status="modified") AND user_activity="active"