CVE-2024-45472

7.8 HIGH

📋 TL;DR

This vulnerability allows memory corruption when parsing malicious WRL files in Siemens Teamcenter Visualization and Tecnomatix Plant Simulation software. Attackers could potentially execute arbitrary code in the context of the current process by exploiting this vulnerability alongside other weaknesses. Organizations using affected versions of these Siemens industrial software products are at risk.

💻 Affected Systems

Products:
  • Teamcenter Visualization
  • Tecnomatix Plant Simulation
Versions: Teamcenter Visualization V14.2 (< V14.2.0.14), V14.3 (< V14.3.0.12), V2312 (< V2312.0008); Tecnomatix Plant Simulation V2302 (< V2302.0016), V2404 (< V2404.0005)
Operating Systems: Windows, Linux
Default Config Vulnerable: ⚠️ Yes
Notes: All installations of affected versions are vulnerable when processing WRL files.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Remote code execution leading to complete system compromise, data theft, or disruption of industrial operations.

🟠

Likely Case

Application crash or denial of service, with potential for limited code execution if combined with other vulnerabilities.

🟢

If Mitigated

Application crash without code execution if proper memory protections and sandboxing are implemented.

🌐 Internet-Facing: MEDIUM - Requires user interaction to open malicious files, but could be delivered via web interfaces or email.
🏢 Internal Only: HIGH - Industrial environments often have these applications on critical systems with elevated privileges.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: MEDIUM

Requires user to open a specially crafted WRL file. Memory corruption vulnerabilities often require additional exploitation techniques for reliable code execution.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Teamcenter Visualization V14.2.0.14, V14.3.0.12, V2312.0008; Tecnomatix Plant Simulation V2302.0016, V2404.0005

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-583523.html

Restart Required: Yes

Instructions:

1. Download appropriate patch from Siemens support portal. 2. Backup current installation. 3. Run installer with administrative privileges. 4. Restart system after installation completes.

🔧 Temporary Workarounds

Restrict WRL file processing

all

Block or restrict processing of WRL files through application settings or system policies.

User awareness training

all

Train users not to open WRL files from untrusted sources.

🧯 If You Can't Patch

  • Implement application whitelisting to prevent execution of unauthorized code
  • Run applications with least privilege and in isolated environments

🔍 How to Verify

Check if Vulnerable:

Check installed version against affected versions list. In application, go to Help > About or check installation directory for version files.

Check Version:

On Windows: Check registry at HKEY_LOCAL_MACHINE\SOFTWARE\Siemens\Teamcenter Visualization\Version or similar paths for Tecnomatix

Verify Fix Applied:

Verify version number matches or exceeds patched versions listed in vendor advisory.

📡 Detection & Monitoring

Log Indicators:

  • Application crashes when processing WRL files
  • Memory access violation errors in application logs

Network Indicators:

  • Unexpected WRL file downloads from external sources
  • Network traffic to/from visualization applications

SIEM Query:

EventID=1000 OR EventID=1001 AND Source='Teamcenter Visualization' OR Source contains 'Tecnomatix'

🔗 References

📤 Share & Export