CVE-2024-41904

7.5 HIGH

📋 TL;DR

SINEC Traffic Analyzer versions before V2.0 lack proper rate limiting on authentication attempts, allowing unauthenticated attackers to perform brute force attacks against user credentials or keys. This affects all users of SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) running versions older than V2.0.

💻 Affected Systems

Products:
  • SINEC Traffic Analyzer (6GK8822-1BG01-0BA0)
Versions: All versions < V2.0
Operating Systems: Not specified
Default Config Vulnerable: ⚠️ Yes
Notes: All installations with default authentication settings are vulnerable.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Attackers could compromise administrative accounts, gain full control of the Traffic Analyzer system, and potentially pivot to other network systems.

🟠

Likely Case

Attackers successfully brute force weaker credentials, gaining unauthorized access to monitor or manipulate network traffic data.

🟢

If Mitigated

With proper rate limiting and strong credentials, attackers would fail to guess credentials before being blocked.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: LIKELY
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Brute force attacks are well-understood and easily automated.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: V2.0

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-716317.html

Restart Required: Yes

Instructions:

1. Download V2.0 from Siemens support portal. 2. Backup configuration. 3. Install update. 4. Restart system.

🔧 Temporary Workarounds

Network-based rate limiting

all

Implement network-level rate limiting or WAF rules to restrict authentication attempts.

Strong credential enforcement

all

Enforce complex passwords and account lockout policies via external authentication systems.

🧯 If You Can't Patch

  • Isolate the Traffic Analyzer behind a firewall with strict access controls.
  • Monitor authentication logs for brute force patterns and implement alerting.

🔍 How to Verify

Check if Vulnerable:

Check the SINEC Traffic Analyzer web interface or system logs for version information.

Check Version:

Not specified; check via web interface or Siemens documentation.

Verify Fix Applied:

Confirm version is V2.0 or higher in system settings.

📡 Detection & Monitoring

Log Indicators:

  • Multiple failed login attempts from single IP
  • Unusual authentication patterns outside business hours

Network Indicators:

  • High volume of HTTP POST requests to login endpoints
  • Traffic from unexpected geolocations

SIEM Query:

source="sinec_traffic_analyzer" event_type="authentication_failure" | stats count by src_ip | where count > 10

🔗 References