CVE-2023-28716

8.8 HIGH

📋 TL;DR

This vulnerability allows authenticated users of mySCADA myPRO versions 8.26.0 and prior to inject arbitrary operating system commands through vulnerable parameters. This could lead to complete system compromise of SCADA/ICS environments. Organizations using affected myPRO versions for industrial control systems are at risk.

💻 Affected Systems

Products:
  • mySCADA myPRO
Versions: 8.26.0 and prior
Operating Systems: Windows, Linux
Default Config Vulnerable: ⚠️ Yes
Notes: Affects all installations of vulnerable versions regardless of configuration. Requires authenticated access to exploit.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Full system compromise allowing attackers to execute arbitrary commands with system privileges, potentially disrupting industrial processes, stealing sensitive data, or causing physical damage.

🟠

Likely Case

Authenticated attackers gaining shell access to the underlying operating system, allowing lateral movement, data exfiltration, or installation of persistent malware.

🟢

If Mitigated

Limited impact if proper network segmentation, least privilege access, and command validation are implemented, though risk remains elevated.

🌐 Internet-Facing: HIGH
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: LIKELY
Unauthenticated Exploit: ✅ No
Complexity: LOW

Requires authenticated access but command injection vulnerabilities are typically easy to exploit once identified.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: 8.26.1 or later

Vendor Advisory: https://www.cisa.gov/news-events/ics-advisories/icsa-23-096-06

Restart Required: Yes

Instructions:

1. Download myPRO version 8.26.1 or later from mySCADA. 2. Backup current configuration and data. 3. Stop myPRO services. 4. Install updated version. 5. Restart services and verify functionality.

🔧 Temporary Workarounds

Input Validation Enhancement

all

Implement strict input validation on all user-controllable parameters to reject shell metacharacters

# Requires code modification - implement parameter validation in application code

Network Segmentation

all

Isolate myPRO systems from untrusted networks and implement strict firewall rules

# Firewall rules will vary by environment

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate myPRO systems from untrusted networks
  • Enforce least privilege access controls and monitor authenticated user activity closely

🔍 How to Verify

Check if Vulnerable:

Check myPRO version in administration interface or configuration files. Versions 8.26.0 and earlier are vulnerable.

Check Version:

Check version in myPRO web interface or configuration files (location varies by installation)

Verify Fix Applied:

Verify installation of version 8.26.1 or later and test parameter inputs for command injection attempts.

📡 Detection & Monitoring

Log Indicators:

  • Unusual command execution patterns
  • Multiple failed authentication attempts followed by successful login and parameter manipulation
  • Suspicious process creation from myPRO service account

Network Indicators:

  • Unexpected outbound connections from myPRO systems
  • Unusual traffic patterns to/from myPRO ports

SIEM Query:

source="myPRO" AND (event_type="command_execution" OR parameter="*;*" OR parameter="*|*" OR parameter="*`*" OR parameter="*$(*")

🔗 References

📤 Share & Export