CVE-2022-24316

7.5 HIGH

📋 TL;DR

This vulnerability in Schneider Electric's Interactive Graphical SCADA System Data Server allows attackers to expose sensitive information by sending specially crafted messages. It affects versions V15.0.0.22020 and earlier, potentially compromising industrial control systems. Organizations using these SCADA systems for critical infrastructure are at risk.

💻 Affected Systems

Products:
  • Interactive Graphical SCADA System Data Server
Versions: V15.0.0.22020 and prior
Operating Systems: Windows
Default Config Vulnerable: ⚠️ Yes
Notes: Affects the Data Server component of the SCADA system; typically deployed in industrial control environments.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Attackers could extract sensitive configuration data, credentials, or operational information from SCADA systems, potentially enabling further attacks on industrial control networks.

🟠

Likely Case

Information disclosure of system data, configuration details, or potentially credentials that could be used for reconnaissance or lateral movement.

🟢

If Mitigated

Limited to no impact if systems are properly segmented, monitored, and patched with appropriate network controls in place.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: MEDIUM

Exploitation requires sending specially crafted messages to the vulnerable component; no authentication needed.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: V15.0.0.22021 or later

Vendor Advisory: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-01

Restart Required: Yes

Instructions:

1. Download the patch from Schneider Electric's security advisory. 2. Apply the patch to affected Data Server installations. 3. Restart the Data Server service. 4. Verify the update was successful.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate SCADA systems from untrusted networks using firewalls and network segmentation.

Access Control

all

Restrict network access to the Data Server to only authorized systems and users.

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate SCADA systems from other networks
  • Deploy intrusion detection systems to monitor for suspicious traffic patterns

🔍 How to Verify

Check if Vulnerable:

Check the Data Server version in the application interface or installation directory; versions V15.0.0.22020 and earlier are vulnerable.

Check Version:

Check the application version in the SCADA Data Server interface or installation properties.

Verify Fix Applied:

Verify the Data Server version is V15.0.0.22021 or later after applying the patch.

📡 Detection & Monitoring

Log Indicators:

  • Unusual message patterns or errors in Data Server logs
  • Failed connection attempts to the Data Server

Network Indicators:

  • Unusual traffic patterns to the Data Server port
  • Suspicious message payloads to the SCADA system

SIEM Query:

source="scada_server" AND (event_type="error" OR message_size>threshold)

🔗 References

📤 Share & Export