CVE-2021-31883
📋 TL;DR
This vulnerability affects Siemens Capital Embedded AR Classic products where the DHCP client fails to validate vendor option lengths in DHCP ACK messages. Attackers can send specially crafted DHCP packets to cause denial-of-service conditions. Affected systems include Capital Embedded AR Classic 431-422 and R20-11 versions.
💻 Affected Systems
- Siemens Capital Embedded AR Classic 431-422
- Siemens Capital Embedded AR Classic R20-11
📦 What is this software?
Apogee Modular Building Controller Firmware by Siemens
View all CVEs affecting Apogee Modular Building Controller Firmware →
Apogee Modular Building Controller Firmware by Siemens
View all CVEs affecting Apogee Modular Building Controller Firmware →
Apogee Modular Equiment Controller Firmware by Siemens
View all CVEs affecting Apogee Modular Equiment Controller Firmware →
Nucleus Net by Siemens
⚠️ Risk & Real-World Impact
Worst Case
Complete system crash or unavailability of affected embedded systems, potentially disrupting industrial operations.
Likely Case
Temporary service disruption or system reboot when malicious DHCP packets are received.
If Mitigated
Minimal impact with proper network segmentation and DHCP server controls.
🎯 Exploit Status
Exploitation requires network access to send malicious DHCP packets to vulnerable systems.
🛠️ Fix & Mitigation
✅ Official Fix
Patch Version: V2303 for R20-11 series
Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-044112.html
Restart Required: Yes
Instructions:
1. Download update V2303 from Siemens support portal. 2. Apply update to affected R20-11 systems. 3. For 431-422 systems, contact Siemens for specific guidance as all versions are affected. 4. Restart systems after patching.
🔧 Temporary Workarounds
Network Segmentation
allIsolate affected systems from untrusted networks and restrict DHCP traffic.
DHCP Server Hardening
allConfigure trusted DHCP servers only and implement DHCP snooping on network switches.
🧯 If You Can't Patch
- Implement strict network segmentation to isolate vulnerable systems
- Deploy network monitoring for anomalous DHCP traffic patterns
🔍 How to Verify
Check if Vulnerable:
Check system version against affected versions: 431-422 (all versions) or R20-11 (versions < V2303)
Check Version:
System-specific Siemens Capital software version check (consult product documentation)
Verify Fix Applied:
Verify system version is V2303 or higher for R20-11 series
📡 Detection & Monitoring
Log Indicators:
- System crash logs
- DHCP client error messages
- Unexpected system reboots
Network Indicators:
- Malformed DHCP packets with oversized vendor options
- DHCP traffic from unauthorized sources
SIEM Query:
DHCP packets with option_length > normal_threshold OR source_ip not in trusted_dhcp_servers
🔗 References
- https://cert-portal.siemens.com/productcert/html/ssa-044112.html
- https://cert-portal.siemens.com/productcert/html/ssa-114589.html
- https://cert-portal.siemens.com/productcert/html/ssa-620288.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf