CVE-2021-22652

9.8 CRITICAL

📋 TL;DR

CVE-2021-22652 is an unauthenticated remote code execution vulnerability in Advantech iView industrial monitoring software. Attackers can access configuration interfaces without credentials, modify settings, and execute arbitrary code. This affects all iView installations prior to version 5.7.03.6112.

💻 Affected Systems

Products:
  • Advantech iView
Versions: All versions prior to v5.7.03.6112
Operating Systems: Windows-based systems running iView
Default Config Vulnerable: ⚠️ Yes
Notes: Affects default installations with no authentication required for configuration access.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system compromise allowing attackers to execute arbitrary code, steal sensitive industrial data, disrupt operations, and pivot to other network systems.

🟠

Likely Case

Unauthorized configuration changes leading to service disruption, data manipulation, and potential ransomware deployment in industrial environments.

🟢

If Mitigated

Limited impact with proper network segmentation and access controls, potentially only configuration viewing without execution.

🌐 Internet-Facing: HIGH - Direct internet exposure allows immediate exploitation without authentication.
🏢 Internal Only: HIGH - Internal attackers or compromised systems can easily exploit this vulnerability.

🎯 Exploit Status

Public PoC: ⚠️ Yes
Weaponized: CONFIRMED
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Public exploit code available on Packet Storm Security. Attack requires no authentication and minimal technical skill.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: v5.7.03.6112 or later

Vendor Advisory: https://us-cert.cisa.gov/ics/advisories/icsa-21-040-02

Restart Required: Yes

Instructions:

1. Download iView v5.7.03.6112 or later from Advantech. 2. Backup current configuration. 3. Stop iView service. 4. Install updated version. 5. Restart service and verify functionality.

🔧 Temporary Workarounds

Network Access Control

windows

Restrict network access to iView interface using firewall rules

# Example Windows firewall rule: netsh advfirewall firewall add rule name="Block iView" dir=in action=block protocol=TCP localport=80,443 remoteip=any

Authentication Proxy

linux

Place iView behind reverse proxy requiring authentication

# Example nginx config: location /iView { auth_basic "Restricted"; auth_basic_user_file /etc/nginx/.htpasswd; proxy_pass http://localhost:8080; }

🧯 If You Can't Patch

  • Isolate iView systems in dedicated VLAN with strict firewall rules allowing only necessary industrial protocol traffic
  • Implement network monitoring and intrusion detection specifically for iView traffic patterns

🔍 How to Verify

Check if Vulnerable:

Access iView configuration interface without credentials. If accessible, system is vulnerable.

Check Version:

Check iView version in web interface or installed programs list

Verify Fix Applied:

Attempt to access configuration interface without credentials. Should receive authentication prompt or access denied.

📡 Detection & Monitoring

Log Indicators:

  • Unauthenticated access to configuration endpoints
  • Unexpected configuration changes
  • New process execution from iView service

Network Indicators:

  • Unusual outbound connections from iView server
  • HTTP requests to configuration endpoints without authentication headers

SIEM Query:

source="iView" AND (url="*/config*" OR url="*/admin*" OR url="*/setup*") AND NOT auth_success="true"

🔗 References

📤 Share & Export