CVE-2020-21992

8.8 HIGH

📋 TL;DR

CVE-2020-21992 allows authenticated attackers to execute arbitrary OS commands with root privileges on Inim Electronics SmartLiving SmartLAN/G/SI devices. The vulnerability exists in the web.cgi binary's testemail module where unsanitized user input is passed to system() calls. Organizations using affected SmartLiving devices with default credentials are at risk.

💻 Affected Systems

Products:
  • Inim Electronics SmartLiving SmartLAN/G/SI
Versions: <= 6.x
Operating Systems: Embedded Linux/ARM
Default Config Vulnerable: ⚠️ Yes
Notes: Requires authentication but default credentials are commonly used. ARM-based embedded systems.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete device compromise allowing attacker to install persistent backdoors, pivot to internal networks, disrupt operations, or use device as part of botnet.

🟠

Likely Case

Attacker gains full control of vulnerable device, potentially accessing connected systems, modifying configurations, or stealing data.

🟢

If Mitigated

Limited impact if strong authentication, network segmentation, and input validation are implemented.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ⚠️ Yes
Weaponized: LIKELY
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploit requires authentication but default credentials are often unchanged. Command injection via 'par' parameter in POST requests to web.cgi.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: > 6.x

Vendor Advisory: https://www.zeroscience.mk/en/vulnerabilities/ZSL-2019-5544.php

Restart Required: Yes

Instructions:

1. Contact Inim Electronics for firmware update >6.x. 2. Download latest firmware. 3. Backup configuration. 4. Apply firmware update via web interface. 5. Reboot device. 6. Verify update.

🔧 Temporary Workarounds

Disable web interface

linux

Disable the vulnerable web.cgi interface if not required

rm /path/to/web.cgi
chmod 000 /path/to/web.cgi

Network segmentation

all

Isolate SmartLiving devices in separate VLAN with strict firewall rules

🧯 If You Can't Patch

  • Change default credentials immediately and enforce strong authentication
  • Implement strict network segmentation and firewall rules to limit device access

🔍 How to Verify

Check if Vulnerable:

Check device firmware version via web interface or SSH. If version <=6.x, device is vulnerable.

Check Version:

ssh admin@device_ip 'cat /etc/version' or check web interface system info

Verify Fix Applied:

Verify firmware version >6.x and test that command injection via 'par' parameter no longer works.

📡 Detection & Monitoring

Log Indicators:

  • Unusual POST requests to web.cgi with testemail module
  • Suspicious commands in system logs
  • Multiple failed authentication attempts

Network Indicators:

  • POST requests to /web.cgi with 'testemail' and 'par' parameters containing shell metacharacters
  • Outbound connections from device to unusual destinations

SIEM Query:

source="device_logs" AND (uri_path="/web.cgi" AND post_data CONTAINS "testemail" AND post_data CONTAINS ["|", ";", "`", "$"] )

🔗 References

📤 Share & Export