CVE-2026-1414

6.3 MEDIUM

📋 TL;DR

This vulnerability allows remote attackers to execute arbitrary commands on Sangfor Operation and Maintenance Security Management System installations up to version 3.0.12. Attackers can exploit the getInformation function via HTTP POST requests with manipulated fortEquipmentIp parameters to inject and execute system commands. Organizations using affected versions of this security management system are at risk.

💻 Affected Systems

Products:
  • Sangfor Operation and Maintenance Security Management System
Versions: Up to and including 3.0.12
Operating Systems: Not specified - likely various
Default Config Vulnerable: ⚠️ Yes
Notes: Affects the HTTP POST request handler component at /equipment/get_Information endpoint

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Full system compromise allowing attackers to execute arbitrary commands with system privileges, potentially leading to data theft, lateral movement, or complete system takeover.

🟠

Likely Case

Remote code execution allowing attackers to install malware, create backdoors, or disrupt security management operations.

🟢

If Mitigated

Limited impact if proper network segmentation, input validation, and least privilege principles are implemented.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ⚠️ Yes
Weaponized: LIKELY
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Exploit has been publicly disclosed and may be utilized. Attack can be launched remotely without authentication.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Unknown

Vendor Advisory: Not available

Restart Required: No

Instructions:

Check with Sangfor for official patches or updates beyond version 3.0.12. Consider upgrading to latest version if available.

🔧 Temporary Workarounds

Network Segmentation

all

Restrict access to the Sangfor management system to trusted networks only

Input Validation

all

Implement strict input validation for fortEquipmentIp parameter

🧯 If You Can't Patch

  • Implement web application firewall (WAF) rules to block suspicious POST requests to /equipment/get_Information
  • Monitor and restrict outbound connections from the Sangfor system to prevent command and control communication

🔍 How to Verify

Check if Vulnerable:

Check system version via Sangfor interface or configuration files. If version is 3.0.12 or earlier, system is vulnerable.

Check Version:

Check Sangfor system administration interface or configuration files for version information

Verify Fix Applied:

Verify system has been updated to version beyond 3.0.12 or test with controlled exploit attempt.

📡 Detection & Monitoring

Log Indicators:

  • Unusual POST requests to /equipment/get_Information
  • Suspicious command execution patterns in system logs
  • Multiple failed authentication attempts followed by successful POST requests

Network Indicators:

  • Unusual outbound connections from Sangfor system
  • POST requests with shell metacharacters in fortEquipmentIp parameter

SIEM Query:

source="sangfor_logs" AND (url_path="/equipment/get_Information" AND http_method="POST" AND (param="fortEquipmentIp" AND value MATCHES "[;&|`$()]"))

🔗 References