CVE-2025-8307
📋 TL;DR
Asseco InfoMedica stores user passwords in an encoded format that can be decoded using an algorithm present in the client-side software. This vulnerability allows attackers with access to the encoded passwords to recover plaintext credentials. All users of affected Asseco InfoMedica versions are impacted.
💻 Affected Systems
- Asseco InfoMedica
⚠️ Manual Verification Required
This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.
Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).
🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.
- Review the CVE details at NVD
- Check vendor security advisories for your specific version
- Test if the vulnerability is exploitable in your environment
- Consider updating to the latest version as a precaution
⚠️ Risk & Real-World Impact
Worst Case
Complete compromise of all user accounts leading to unauthorized access to sensitive medical and administrative data, potential data manipulation, and system takeover.
Likely Case
Attackers with database access can decode passwords to gain unauthorized access to user accounts, potentially accessing sensitive healthcare information.
If Mitigated
With proper access controls and monitoring, impact is limited to credential exposure requiring password resets.
🎯 Exploit Status
Exploitation requires access to the encoded passwords from the database and knowledge of the client-side decoding algorithm.
🛠️ Fix & Mitigation
✅ Official Fix
Patch Version: 4.50.1 or 5.38.0
Vendor Advisory: https://cert.pl/en/posts/2026/01/CVE-2025-8306/
Restart Required: Yes
Instructions:
1. Backup database and application. 2. Download and install version 4.50.1 (for v4.x) or 5.38.0 (for v5.x). 3. Restart application services. 4. Force password reset for all users.
🔧 Temporary Workarounds
Restrict Database Access
allLimit access to the database containing encoded passwords to authorized personnel only.
Implement Network Segmentation
allIsolate the InfoMedica database server from untrusted networks and limit client connections.
🧯 If You Can't Patch
- Implement strong access controls to prevent unauthorized database access
- Enable comprehensive logging and monitoring of database access attempts
🔍 How to Verify
Check if Vulnerable:
Check application version in administration panel or configuration files. If version is below 4.50.1 (for v4.x) or 5.38.0 (for v5.x), system is vulnerable.
Check Version:
Check application configuration or administration interface for version information
Verify Fix Applied:
Confirm version is 4.50.1 or higher (v4.x) or 5.38.0 or higher (v5.x) and verify password storage uses proper hashing instead of reversible encoding.
📡 Detection & Monitoring
Log Indicators:
- Unusual database access patterns
- Multiple failed login attempts followed by successful logins
- Access from unexpected IP addresses
Network Indicators:
- Unusual database query patterns
- Excessive data extraction from database
SIEM Query: