CVE-2025-40838

7.5 HIGH

📋 TL;DR

Ericsson Indoor Connect 8855 has a server-side security bypass vulnerability in the client component that allows attackers to circumvent authentication mechanisms. This can lead to unauthorized access to sensitive information stored on or accessible through the system. Organizations using Ericsson Indoor Connect 8855 are affected.

💻 Affected Systems

Products:
  • Ericsson Indoor Connect 8855
Versions: All versions prior to patch
Operating Systems: Embedded system
Default Config Vulnerable: ⚠️ Yes
Notes: The vulnerability exists in the client-server communication component of the Indoor Connect system.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete compromise of the Indoor Connect system allowing attackers to access all connected devices, configuration data, and potentially pivot to other network segments.

🟠

Likely Case

Unauthorized access to sensitive configuration data, device status information, and network topology details that could facilitate further attacks.

🟢

If Mitigated

Limited information disclosure if proper network segmentation and access controls are implemented, though the vulnerability still exists.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

The vulnerability allows bypassing server-side security controls from the client side, suggesting relatively straightforward exploitation.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Check vendor advisory for specific patched version

Vendor Advisory: https://www.ericsson.com/en/about-us/security/psirt/e2025-09-25

Restart Required: Yes

Instructions:

1. Review the Ericsson security advisory E2025-09-25
2. Download the latest firmware/software update from Ericsson
3. Backup current configuration
4. Apply the update following Ericsson's deployment guide
5. Restart the Indoor Connect system
6. Verify the update was successful

🔧 Temporary Workarounds

Network Segmentation

all

Isolate the Indoor Connect system from untrusted networks and limit access to authorized management systems only.

Access Control Lists

all

Implement strict firewall rules to only allow necessary communication to/from the Indoor Connect system.

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate the Indoor Connect system from critical infrastructure
  • Monitor all access to the Indoor Connect system and implement alerting for unauthorized access attempts

🔍 How to Verify

Check if Vulnerable:

Check the current firmware version against the patched version specified in Ericsson advisory E2025-09-25

Check Version:

Check via the Indoor Connect web interface or CLI (specific command varies by version)

Verify Fix Applied:

Verify the firmware version matches or exceeds the patched version from the Ericsson advisory

📡 Detection & Monitoring

Log Indicators:

  • Unauthorized access attempts to Indoor Connect management interfaces
  • Unusual authentication patterns or bypass attempts
  • Access from unexpected IP addresses or networks

Network Indicators:

  • Unusual traffic patterns to/from Indoor Connect systems
  • Authentication bypass attempts in network traffic

SIEM Query:

source="indoor_connect" AND (event_type="auth_failure" OR event_type="access_denied")

🔗 References

📤 Share & Export