CVE-2025-40743

8.3 HIGH

📋 TL;DR

This vulnerability allows attackers to bypass authentication on Siemens SINUMERIK CNC systems' VNC access service due to insufficient password verification. Affected systems include multiple SINUMERIK 828D, 840D sl, MC, and ONE models running vulnerable firmware versions. Successful exploitation could lead to unauthorized remote access to industrial control systems.

💻 Affected Systems

Products:
  • SINUMERIK 828D PPU.4
  • SINUMERIK 828D PPU.5
  • SINUMERIK 840D sl
  • SINUMERIK MC
  • SINUMERIK MC V1.15
  • SINUMERIK ONE
  • SINUMERIK ONE V6.15
Versions: All versions below: 828D PPU.4 V4.95 SP5, 828D PPU.5 V5.25 SP1, 840D sl V4.95 SP5, MC V1.25 SP1, MC V1.15 V1.15 SP5, ONE V6.25 SP1, ONE V6.15 V6.15 SP5
Operating Systems: SINUMERIK firmware
Default Config Vulnerable: ⚠️ Yes
Notes: Vulnerability affects the VNC access service authentication mechanism. Systems with VNC enabled are vulnerable by default.

⚠️ Manual Verification Required

This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.

Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).

🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.

Recommended Actions:
  1. Review the CVE details at NVD
  2. Check vendor security advisories for your specific version
  3. Test if the vulnerability is exploitable in your environment
  4. Consider updating to the latest version as a precaution

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete compromise of CNC system allowing unauthorized control of industrial machinery, potential physical damage, production disruption, and theft of proprietary manufacturing data.

🟠

Likely Case

Unauthorized access to CNC system interface allowing monitoring of operations, configuration changes, and potential disruption of manufacturing processes.

🟢

If Mitigated

Limited impact if systems are air-gapped, have network segmentation, or VNC service is disabled.

🌐 Internet-Facing: HIGH - VNC services exposed to internet would be directly vulnerable to remote exploitation without authentication.
🏢 Internal Only: HIGH - Even internally, insufficient authentication allows any network-connected attacker to gain access.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Authentication bypass vulnerabilities typically require minimal technical skill to exploit once details are known. No public exploit code identified at this time.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Update to: 828D PPU.4 V4.95 SP5, 828D PPU.5 V5.25 SP1, 840D sl V4.95 SP5, MC V1.25 SP1, MC V1.15 V1.15 SP5, ONE V6.25 SP1, ONE V6.15 V6.15 SP5

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-177847.html

Restart Required: Yes

Instructions:

1. Download appropriate firmware update from Siemens support portal
2. Backup current configuration and programs
3. Apply firmware update following Siemens documentation
4. Restart system
5. Verify update was successful

🔧 Temporary Workarounds

Disable VNC Service

sinumerik

Disable the vulnerable VNC access service if remote access is not required.

Configure via SINUMERIK HMI: System > Service > VNC > Disable

Network Segmentation

all

Isolate SINUMERIK systems from untrusted networks using firewalls.

Configure firewall rules to block VNC port (typically 5900/tcp) from unauthorized networks

🧯 If You Can't Patch

  • Implement strict network access controls to limit VNC service access to authorized IP addresses only.
  • Monitor VNC authentication logs for unauthorized access attempts and implement alerting.

🔍 How to Verify

Check if Vulnerable:

Check firmware version via SINUMERIK HMI: System > Version > Display version information and compare against patched versions.

Check Version:

On SINUMERIK HMI: Navigate to System > Version > Display version information

Verify Fix Applied:

Verify firmware version shows patched version and test VNC authentication requires proper credentials.

📡 Detection & Monitoring

Log Indicators:

  • Failed VNC authentication attempts followed by successful access
  • VNC connections from unexpected IP addresses
  • Multiple rapid VNC connection attempts

Network Indicators:

  • VNC protocol traffic (port 5900/tcp) from unauthorized sources
  • Unencrypted VNC authentication attempts

SIEM Query:

source="sinumerik_logs" AND (event="vnc_auth" AND result="success") AND NOT src_ip IN [authorized_ips]

🔗 References

📤 Share & Export