CVE-2025-40583

4.4 MEDIUM

📋 TL;DR

SCALANCE LPE9403 devices with SINEMA Remote Connect Edge Client transmit sensitive information in cleartext, allowing privileged local attackers to intercept this data. This affects all versions of the specified hardware with the vulnerable client installed.

💻 Affected Systems

Products:
  • SCALANCE LPE9403 (6GK5998-3GS00-2AC2)
Versions: All versions with SINEMA Remote Connect Edge Client installed
Operating Systems: Embedded industrial OS
Default Config Vulnerable: ⚠️ Yes
Notes: Only vulnerable when SINEMA Remote Connect Edge Client is installed on the specified hardware model.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Privileged local attacker obtains sensitive configuration data, credentials, or network information that could facilitate further attacks on industrial control systems.

🟠

Likely Case

Authorized local user with administrative access captures transmitted sensitive data, potentially compromising device security or network integrity.

🟢

If Mitigated

With proper network segmentation and access controls, impact is limited to isolated systems with minimal exposure.

🌐 Internet-Facing: LOW - Requires local privileged access, not directly exploitable over internet.
🏢 Internal Only: MEDIUM - Local privileged access required, but industrial networks often have multiple authorized users who could exploit this.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploitation requires local privileged access to intercept cleartext transmissions.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Check Siemens advisory for specific patched versions

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-327438.html

Restart Required: Yes

Instructions:

1. Review Siemens advisory SSA-327438. 2. Apply recommended updates to SINEMA Remote Connect Edge Client. 3. Restart affected devices. 4. Verify encryption is properly implemented.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate affected devices to limit exposure to privileged local attackers

Access Control Hardening

all

Restrict local administrative access to only essential personnel

🧯 If You Can't Patch

  • Implement network monitoring for cleartext transmissions from affected devices
  • Deploy additional authentication controls and audit privileged local access

🔍 How to Verify

Check if Vulnerable:

Check if SCALANCE LPE9403 (6GK5998-3GS00-2AC2) has SINEMA Remote Connect Edge Client installed via device management interface

Check Version:

Check via SINEMA Remote Connect management interface or device console

Verify Fix Applied:

Verify SINEMA Remote Connect Edge Client version matches patched version from Siemens advisory and monitor for encrypted transmissions

📡 Detection & Monitoring

Log Indicators:

  • Unusual local privileged access attempts
  • Cleartext data transmission logs

Network Indicators:

  • Cleartext protocol traffic from SCALANCE devices on internal networks

SIEM Query:

source_ip:SCALANCE_DEVICE AND protocol:unencrypted AND (data_length > threshold)

🔗 References

📤 Share & Export