CVE-2025-40568

4.3 MEDIUM

📋 TL;DR

This vulnerability allows authenticated remote attackers with 'guest' role privileges to terminate legitimate user sessions in affected Siemens industrial network devices. It affects multiple RUGGEDCOM and SCALANCE product lines running versions below V3.2. The flaw stems from an incorrect authorization check in the web interface's session termination functionality.

💻 Affected Systems

Products:
  • RUGGEDCOM RST2428P (6GK6242-6PA00)
  • SCALANCE XCH328 (6GK5328-4TS01-2EC2)
  • SCALANCE XCM324 (6GK5324-8TS01-2AC2)
  • SCALANCE XCM328 (6GK5328-4TS01-2AC2)
  • SCALANCE XCM332 (6GK5332-0GA01-2AC2)
  • SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
  • SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
  • SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
  • SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3)
  • SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
  • SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
  • SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3)
  • SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
  • SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
  • SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3)
Versions: All versions < V3.2
Operating Systems: Embedded firmware
Default Config Vulnerable: ⚠️ Yes
Notes: All listed products with firmware versions below V3.2 are affected. The vulnerability requires web interface access and guest-level credentials.

⚠️ Manual Verification Required

This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.

Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).

🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.

Recommended Actions:
  1. Review the CVE details at NVD
  2. Check vendor security advisories for your specific version
  3. Test if the vulnerability is exploitable in your environment
  4. Consider updating to the latest version as a precaution

⚠️ Risk & Real-World Impact

🔴

Worst Case

An attacker could disrupt operations by terminating administrator sessions during critical maintenance or configuration changes, potentially causing service interruptions in industrial environments.

🟠

Likely Case

Guest users could disrupt other users' sessions, causing temporary access issues and requiring re-authentication, but without direct data compromise or system takeover.

🟢

If Mitigated

With proper network segmentation and role-based access controls, impact is limited to minor service disruptions requiring user re-authentication.

🌐 Internet-Facing: MEDIUM - Devices exposed to internet could be targeted, but attacker needs guest credentials and impact is limited to session termination.
🏢 Internal Only: MEDIUM - Internal attackers with guest access could disrupt legitimate user sessions, but requires authenticated access and doesn't provide privilege escalation.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploitation requires authenticated access with guest role privileges. The vulnerability is in the web interface's authorization logic.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: V3.2 or later

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-693776.html

Restart Required: Yes

Instructions:

1. Download firmware V3.2 or later from Siemens support portal. 2. Backup current configuration. 3. Upload and install new firmware via web interface or management tools. 4. Reboot device. 5. Restore configuration if needed. 6. Verify version is V3.2 or higher.

🔧 Temporary Workarounds

Restrict Guest Access

all

Remove or restrict guest account access to web interface

Configure via web interface: System > User Management > Modify guest role permissions

Network Segmentation

all

Isolate affected devices from untrusted networks and limit access to authorized users only

🧯 If You Can't Patch

  • Implement strict network access controls to limit web interface access to trusted users only
  • Disable or remove guest accounts entirely from affected devices

🔍 How to Verify

Check if Vulnerable:

Check firmware version via web interface: System > Device Information > Firmware Version. If version is below V3.2, device is vulnerable.

Check Version:

Web interface: System > Device Information > Firmware Version field

Verify Fix Applied:

After patching, verify firmware version is V3.2 or higher in System > Device Information. Test with guest account that session termination functionality now properly validates authorization.

📡 Detection & Monitoring

Log Indicators:

  • Multiple session termination events from guest accounts
  • Users reporting unexpected session timeouts or forced logouts

Network Indicators:

  • HTTP POST requests to session termination endpoints from guest accounts
  • Unusual session management traffic patterns

SIEM Query:

source="industrial_switch" AND (event_type="session_termination" AND user_role="guest")

🔗 References

📤 Share & Export