CVE-2025-32825

8.8 HIGH

📋 TL;DR

An SQL injection vulnerability in TeleControl Server Basic allows authenticated attackers to bypass authorization, read/write to the database, and execute code with NetworkService permissions. This affects all versions before V3.1.2.2. Attackers need access to port 8000 on systems running vulnerable versions.

💻 Affected Systems

Products:
  • TeleControl Server Basic
Versions: All versions < V3.1.2.2
Operating Systems: Windows
Default Config Vulnerable: ⚠️ Yes
Notes: Requires authentication and access to port 8000. NetworkService permissions provide significant system access.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Full system compromise with code execution as NT AUTHORITY\NetworkService, allowing lateral movement, data theft, and persistence.

🟠

Likely Case

Database manipulation, credential theft, and privilege escalation leading to operational disruption.

🟢

If Mitigated

Limited impact with proper network segmentation and authentication controls, potentially only unauthorized data access.

🌐 Internet-Facing: HIGH
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: LOW

SQL injection via GetProjects method requires authenticated access but is straightforward once authenticated.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: V3.1.2.2

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-443402.html

Restart Required: Yes

Instructions:

1. Download V3.1.2.2 from Siemens support portal. 2. Backup configuration and data. 3. Install update following vendor documentation. 4. Restart TeleControl Server Basic service.

🔧 Temporary Workarounds

Network Access Restriction

windows

Restrict access to port 8000/TCP to only trusted IP addresses or networks.

Windows Firewall: New-NetFirewallRule -DisplayName "Block TeleControl Port" -Direction Inbound -LocalPort 8000 -Protocol TCP -Action Block

Application Layer Filtering

all

Implement WAF rules to block SQL injection patterns targeting the GetProjects method.

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate TeleControl Server Basic from untrusted networks.
  • Enforce strong authentication mechanisms and monitor for unusual database queries or authentication attempts.

🔍 How to Verify

Check if Vulnerable:

Check TeleControl Server Basic version in application interface or registry: HKEY_LOCAL_MACHINE\SOFTWARE\Siemens\TeleControl Server Basic\Version

Check Version:

reg query "HKLM\SOFTWARE\Siemens\TeleControl Server Basic" /v Version

Verify Fix Applied:

Confirm version is V3.1.2.2 or higher and test GetProjects functionality with SQL injection test payloads.

📡 Detection & Monitoring

Log Indicators:

  • Unusual SQL queries in application logs
  • Failed authentication attempts followed by database access
  • NetworkService account performing unexpected actions

Network Indicators:

  • SQL injection patterns in traffic to port 8000
  • Unusual outbound connections from TeleControl Server system

SIEM Query:

source="TeleControl_Logs" AND ("GetProjects" AND ("UNION" OR "SELECT" OR "INSERT" OR "DELETE"))

🔗 References

📤 Share & Export