CVE-2025-31644

8.7 HIGH

📋 TL;DR

A command injection vulnerability in F5 BIG-IP Appliance mode allows authenticated administrators to execute arbitrary system commands, potentially crossing security boundaries. This affects BIG-IP systems running vulnerable versions in Appliance mode configuration.

💻 Affected Systems

Products:
  • F5 BIG-IP
Versions: Specific versions not disclosed in CVE description; refer to F5 advisory K000148591
Operating Systems: F5 TMOS
Default Config Vulnerable: ✅ No
Notes: Only vulnerable when running in Appliance mode. Requires administrator role privileges for exploitation.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system compromise allowing attacker to execute arbitrary commands with highest privileges, potentially accessing sensitive data, modifying configurations, or establishing persistence.

🟠

Likely Case

Privilege escalation within the appliance environment leading to unauthorized access to restricted system components or data.

🟢

If Mitigated

Limited impact due to proper access controls, network segmentation, and monitoring preventing successful exploitation.

🌐 Internet-Facing: HIGH - BIG-IP devices are often internet-facing load balancers and application delivery controllers.
🏢 Internal Only: HIGH - Even internally, compromised BIG-IP devices can provide access to critical infrastructure.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: LOW

Requires authenticated administrator access. Command injection vulnerabilities are typically straightforward to exploit once identified.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Refer to F5 advisory K000148591 for specific fixed versions

Vendor Advisory: https://my.f5.com/manage/s/article/K000148591

Restart Required: Yes

Instructions:

1. Review F5 advisory K000148591 for affected versions. 2. Upgrade to patched version. 3. Restart BIG-IP services. 4. Verify patch application.

🔧 Temporary Workarounds

Restrict Administrator Access

all

Limit administrator role access to only necessary personnel and implement strong authentication controls.

Disable Appliance Mode if Not Required

all

If Appliance mode is not needed for your deployment, consider disabling it.

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate BIG-IP devices
  • Enforce least privilege access controls and monitor administrator activity

🔍 How to Verify

Check if Vulnerable:

Check if running in Appliance mode and compare version against F5 advisory K000148591

Check Version:

tmsh show sys version

Verify Fix Applied:

Verify version is updated to patched release listed in F5 advisory

📡 Detection & Monitoring

Log Indicators:

  • Unusual tmsh command execution patterns
  • Suspicious system command execution from iControl REST

Network Indicators:

  • Anomalous outbound connections from BIG-IP management interfaces

SIEM Query:

source="bigip" AND (event_type="command_execution" OR process="tmsh") AND command="*;*" OR command="*|*" OR command="*`*"

🔗 References