CVE-2025-31350

8.8 HIGH

📋 TL;DR

This SQL injection vulnerability in TeleControl Server Basic allows authenticated remote attackers to bypass authorization controls, read/write to the database, and execute code with NetworkService permissions. It affects all versions before V3.1.2.2. Attackers need access to port 8000 on systems running vulnerable versions.

💻 Affected Systems

Products:
  • TeleControl Server Basic
Versions: All versions < V3.1.2.2
Operating Systems: Windows
Default Config Vulnerable: ⚠️ Yes
Notes: Requires port 8000 accessible and authenticated access to the application.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system compromise with NetworkService privileges leading to lateral movement, data exfiltration, and persistent backdoor installation.

🟠

Likely Case

Database manipulation, credential theft, and privilege escalation within the application environment.

🟢

If Mitigated

Limited impact due to network segmentation, strong authentication controls, and monitoring preventing successful exploitation.

🌐 Internet-Facing: HIGH
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: LIKELY
Unauthenticated Exploit: ✅ No
Complexity: LOW

SQL injection via UpdateBufferingSettings method requires authentication but has low technical complexity once authenticated.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: V3.1.2.2

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-443402.html

Restart Required: Yes

Instructions:

1. Download V3.1.2.2 from Siemens support portal. 2. Backup configuration and data. 3. Stop TeleControl Server Basic service. 4. Install update. 5. Restart service and verify functionality.

🔧 Temporary Workarounds

Network Segmentation

windows

Restrict access to port 8000 to only trusted networks and users

Windows Firewall: New-NetFirewallRule -DisplayName "Block TeleControl Port" -Direction Inbound -LocalPort 8000 -Protocol TCP -Action Block

Authentication Hardening

all

Implement strong authentication controls and monitor for suspicious login attempts

🧯 If You Can't Patch

  • Implement strict network access controls to limit port 8000 exposure
  • Deploy web application firewall with SQL injection protection rules

🔍 How to Verify

Check if Vulnerable:

Check TeleControl Server Basic version in application interface or installation directory

Check Version:

Check application GUI or installation directory for version information

Verify Fix Applied:

Verify version is V3.1.2.2 or higher in application interface

📡 Detection & Monitoring

Log Indicators:

  • Unusual database queries
  • Multiple failed authentication attempts followed by successful login
  • Unexpected process execution with NetworkService context

Network Indicators:

  • SQL-like patterns in traffic to port 8000
  • Unusual outbound connections from TeleControl Server

SIEM Query:

source="TeleControl" AND (event_description="SQL" OR event_description="injection") OR destination_port=8000 AND payload_contains="SELECT|INSERT|UPDATE|DELETE"

🔗 References

📤 Share & Export