CVE-2025-0593

8.8 HIGH

📋 TL;DR

This vulnerability allows remote attackers with low privileges to execute arbitrary shell commands on affected SICK devices by exploiting improper neutralization of special elements used in a command. Organizations using vulnerable SICK industrial devices are affected.

💻 Affected Systems

Products:
  • SICK industrial devices (specific models detailed in vendor advisory)
Versions: Multiple versions prior to patched releases
Operating Systems: Embedded/industrial OS on SICK devices
Default Config Vulnerable: ⚠️ Yes
Notes: Devices with network connectivity and exposed services are vulnerable. Default configurations may be exploitable.

⚠️ Manual Verification Required

This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.

Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).

🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.

Recommended Actions:
  1. Review the CVE details at NVD
  2. Check vendor security advisories for your specific version
  3. Test if the vulnerability is exploitable in your environment
  4. Consider updating to the latest version as a precaution

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system compromise allowing attackers to execute arbitrary commands, potentially leading to device takeover, data exfiltration, or disruption of industrial operations.

🟠

Likely Case

Attackers gain shell access to execute limited commands, potentially enabling lateral movement, data theft, or service disruption.

🟢

If Mitigated

With proper network segmentation and access controls, impact is limited to isolated systems with minimal business disruption.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: MEDIUM

Requires low-privileged access to exploit. No public exploit code available at this time.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Refer to SICK advisory SCA-2025-0002 for specific patched versions

Vendor Advisory: https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0002.json

Restart Required: No

Instructions:

1. Review SICK advisory SCA-2025-0002. 2. Identify affected devices. 3. Apply firmware updates provided by SICK. 4. Verify update completion.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate affected devices from untrusted networks and implement strict firewall rules

Access Control Restrictions

all

Limit user privileges and implement principle of least privilege for device access

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate vulnerable devices
  • Deploy intrusion detection systems to monitor for exploitation attempts

🔍 How to Verify

Check if Vulnerable:

Check device firmware version against vulnerable versions listed in SICK advisory SCA-2025-0002

Check Version:

Device-specific command (consult SICK documentation for exact command)

Verify Fix Applied:

Verify firmware version matches patched versions in vendor advisory and test functionality

📡 Detection & Monitoring

Log Indicators:

  • Unusual shell command execution
  • Unauthorized access attempts
  • Abnormal process creation

Network Indicators:

  • Suspicious network traffic to device management interfaces
  • Unexpected outbound connections

SIEM Query:

source="device_logs" AND (event="command_execution" OR event="shell_access") AND user!="authorized_user"

🔗 References

📤 Share & Export