CVE-2024-7007

9.8 CRITICAL

📋 TL;DR

CVE-2024-7007 is an authentication bypass vulnerability in Positron Broadcast Signal Processor TRA7005 v1.20 that allows attackers to access protected application areas without valid credentials. This affects all organizations using the vulnerable version of this industrial control system (ICS) equipment for broadcast signal processing.

💻 Affected Systems

Products:
  • Positron Broadcast Signal Processor TRA7005
Versions: v1.20
Operating Systems: Embedded/Proprietary
Default Config Vulnerable: ⚠️ Yes
Notes: Specifically affects the web interface/management console of the broadcast signal processor. Industrial control system equipment used in broadcast environments.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete compromise of broadcast signal processing systems allowing unauthorized signal manipulation, service disruption, or installation of persistent backdoors in critical broadcast infrastructure.

🟠

Likely Case

Unauthorized access to administrative interfaces leading to configuration changes, signal interference, or data exfiltration from broadcast systems.

🟢

If Mitigated

Limited impact if systems are air-gapped with strict network segmentation and access controls, though authentication bypass remains possible for authorized users.

🌐 Internet-Facing: HIGH - If exposed to internet, attackers can easily bypass authentication and compromise systems remotely.
🏢 Internal Only: MEDIUM - Internal attackers or compromised internal systems could exploit this, but requires some network access.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: LIKELY
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Authentication bypass vulnerabilities typically have low exploitation complexity. CISA advisory suggests active exploitation is possible.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Check with vendor for updated version

Vendor Advisory: https://www.cisa.gov/news-events/ics-advisories/icsa-24-207-02

Restart Required: Yes

Instructions:

1. Contact Positron for updated firmware. 2. Backup current configuration. 3. Apply firmware update following vendor instructions. 4. Restart device. 5. Verify authentication controls are functioning.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate TRA7005 devices from untrusted networks and internet access

Access Control Lists

all

Implement strict firewall rules limiting access to management interface

🧯 If You Can't Patch

  • Implement network segmentation to isolate vulnerable devices in separate VLAN with strict access controls
  • Deploy network-based intrusion detection systems to monitor for authentication bypass attempts and unauthorized access

🔍 How to Verify

Check if Vulnerable:

Check device firmware version via web interface or serial console. If version is v1.20, device is vulnerable.

Check Version:

Check via web interface at /status or via serial console using vendor-specific commands

Verify Fix Applied:

After patching, attempt to access protected areas without authentication to confirm bypass is no longer possible.

📡 Detection & Monitoring

Log Indicators:

  • Failed authentication attempts followed by successful access
  • Access to protected URLs without preceding auth logs
  • Multiple access attempts from single IP to admin endpoints

Network Indicators:

  • HTTP requests to protected endpoints without authentication headers
  • Traffic to /admin or similar protected paths from unauthorized sources

SIEM Query:

source="tra7005" AND (event_type="auth_failure" OR event_type="admin_access") | stats count by src_ip, user

🔗 References

📤 Share & Export