CVE-2024-5560

5.3 MEDIUM

📋 TL;DR

This CVE describes an out-of-bounds read vulnerability in Schneider Electric devices that allows attackers to cause denial of service of the web interface by sending specially crafted HTTP requests. The vulnerability affects Schneider Electric products with vulnerable web interfaces, potentially impacting industrial control systems and critical infrastructure.

💻 Affected Systems

Products:
  • Schneider Electric products with vulnerable web interfaces (specific products not detailed in provided references)
Versions: Not specified in provided references
Operating Systems: Embedded systems in Schneider Electric devices
Default Config Vulnerable: ⚠️ Yes
Notes: Affects devices with web interfaces enabled. The specific Schneider Electric products affected are detailed in the vendor advisory PDFs.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete unavailability of the device's web management interface, requiring physical access to restore functionality, potentially disrupting industrial operations.

🟠

Likely Case

Temporary denial of service of the web interface, requiring device restart to restore web management capabilities.

🟢

If Mitigated

Minimal impact with proper network segmentation and access controls limiting HTTP requests to trusted sources only.

🌐 Internet-Facing: HIGH - Web interfaces exposed to the internet can be easily targeted with crafted HTTP requests.
🏢 Internal Only: MEDIUM - Internal attackers or compromised internal systems could exploit this to disrupt management interfaces.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Exploitation requires sending crafted HTTP requests to the web interface, which is typically unauthenticated for basic requests.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Refer to vendor advisory for specific fixed versions

Vendor Advisory: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf

Restart Required: Yes

Instructions:

1. Download the security patch from Schneider Electric's website. 2. Apply the patch according to vendor instructions. 3. Restart the device to apply changes. 4. Verify the web interface functions normally.

🔧 Temporary Workarounds

Network Segmentation

all

Restrict access to device web interfaces using firewall rules or network segmentation

Disable Web Interface

all

Temporarily disable the web interface if not required for operations

🧯 If You Can't Patch

  • Implement strict network access controls to limit HTTP traffic to trusted IP addresses only
  • Monitor web interface logs for unusual HTTP request patterns and implement rate limiting

🔍 How to Verify

Check if Vulnerable:

Check device version against vendor advisory and test with controlled HTTP request patterns

Check Version:

Check device web interface or console for firmware version information

Verify Fix Applied:

Verify device version matches patched version in vendor advisory and test web interface functionality

📡 Detection & Monitoring

Log Indicators:

  • Unusual HTTP request patterns to web interface
  • Web interface crash or restart logs
  • Multiple malformed HTTP requests from single source

Network Indicators:

  • Spike in HTTP traffic to device web interface
  • HTTP requests with unusual headers or parameters

SIEM Query:

source_ip="device_ip" AND (http_request CONTAINS "malformed" OR http_status="500")

🔗 References

📤 Share & Export