CVE-2024-52567

7.8 HIGH

📋 TL;DR

This vulnerability allows remote code execution through specially crafted WRL files in Siemens Teamcenter Visualization and Tecnomatix Plant Simulation software. An attacker could execute arbitrary code in the context of the current process by tricking a user into opening a malicious file. Organizations using affected versions of these Siemens industrial software products are at risk.

💻 Affected Systems

Products:
  • Teamcenter Visualization
  • Tecnomatix Plant Simulation
Versions: Teamcenter Visualization V14.2 (< V14.2.0.14), V14.3 (< V14.3.0.12), V2312 (< V2312.0008), V2406 (< V2406.0005); Tecnomatix Plant Simulation V2302 (< V2302.0018), V2404 (< V2404.0007)
Operating Systems: Windows, Linux
Default Config Vulnerable: ⚠️ Yes
Notes: All affected versions are vulnerable by default when processing WRL files. The vulnerability affects both Windows and Linux versions of these Siemens applications.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system compromise with attacker gaining the same privileges as the user running the vulnerable application, potentially leading to data theft, system manipulation, or lateral movement within the network.

🟠

Likely Case

Local privilege escalation or system compromise when users open malicious WRL files, potentially leading to data exfiltration or installation of persistent malware.

🟢

If Mitigated

Limited impact if proper application whitelisting, file type restrictions, and least privilege principles are implemented, though the vulnerability still exists.

🌐 Internet-Facing: MEDIUM
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: MEDIUM

Exploitation requires user interaction to open a malicious WRL file. No public exploit code is currently available, but the vulnerability is documented by ZDI (ZDI-CAN-24237).

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Teamcenter Visualization V14.2.0.14, V14.3.0.12, V2312.0008, V2406.0005; Tecnomatix Plant Simulation V2302.0018, V2404.0007

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-645131.html

Restart Required: Yes

Instructions:

1. Download the appropriate patch from Siemens Support Portal. 2. Backup current installation. 3. Apply the patch following Siemens installation instructions. 4. Restart the application and verify functionality.

🔧 Temporary Workarounds

Restrict WRL file processing

all

Block or restrict processing of WRL files through application controls or group policy

User awareness training

all

Train users not to open WRL files from untrusted sources

🧯 If You Can't Patch

  • Implement application whitelisting to restrict execution of vulnerable software versions
  • Use network segmentation to isolate systems running vulnerable software from critical assets

🔍 How to Verify

Check if Vulnerable:

Check the installed version of Teamcenter Visualization or Tecnomatix Plant Simulation against the affected version ranges

Check Version:

Check Help > About in the application interface or consult Siemens documentation for version verification commands

Verify Fix Applied:

Verify the installed version matches or exceeds the patched versions listed in the vendor advisory

📡 Detection & Monitoring

Log Indicators:

  • Application crashes when processing WRL files
  • Unusual process creation from visualization applications
  • Failed file parsing attempts in application logs

Network Indicators:

  • Unexpected outbound connections from visualization workstations
  • File transfers of WRL files to visualization systems

SIEM Query:

Process creation events from Teamcenter Visualization or Tecnomatix Plant Simulation followed by suspicious network connections or file access

🔗 References