CVE-2024-52335

9.8 CRITICAL

📋 TL;DR

This is a critical SQL injection vulnerability in Siemens Healthineers syngo.plaza VB30E medical imaging software. Attackers with application access can execute arbitrary SQL commands to compromise the entire database. All versions before VB30E_HF05 are affected.

💻 Affected Systems

Products:
  • Siemens Healthineers syngo.plaza VB30E
Versions: All versions < VB30E_HF05
Operating Systems: Windows-based medical imaging systems
Default Config Vulnerable: ⚠️ Yes
Notes: Medical imaging systems in healthcare environments, typically connected to hospital networks.

⚠️ Manual Verification Required

This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.

Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).

🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.

Recommended Actions:
  1. Review the CVE details at NVD
  2. Check vendor security advisories for your specific version
  3. Test if the vulnerability is exploitable in your environment
  4. Consider updating to the latest version as a precaution

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete database compromise including patient data exfiltration, data manipulation, system takeover, and potential lateral movement to connected systems.

🟠

Likely Case

Data theft of sensitive medical information, potential disruption of medical imaging services, and compliance violations.

🟢

If Mitigated

Limited impact with proper network segmentation, database permissions, and input validation controls in place.

🌐 Internet-Facing: HIGH if exposed to internet, as SQL injection can be exploited remotely through web interfaces.
🏢 Internal Only: HIGH due to potential for authenticated users or compromised accounts to exploit the vulnerability.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: LOW

Requires application access but SQL injection is well-understood and easily weaponized once discovered.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: VB30E_HF05

Vendor Advisory: https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-160244

Restart Required: Yes

Instructions:

1. Download VB30E_HF05 hotfix from Siemens Healthineers support portal. 2. Apply hotfix following vendor instructions. 3. Restart the syngo.plaza application. 4. Verify successful installation.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate syngo.plaza systems from untrusted networks and implement strict firewall rules.

Database Permissions

all

Implement least privilege database accounts with minimal permissions required for application functionality.

🧯 If You Can't Patch

  • Implement web application firewall (WAF) with SQL injection rules
  • Enable database auditing and monitor for suspicious SQL queries

🔍 How to Verify

Check if Vulnerable:

Check syngo.plaza version in application interface or configuration files. If version is earlier than VB30E_HF05, system is vulnerable.

Check Version:

Check through syngo.plaza application interface or consult Siemens Healthineers documentation for version verification.

Verify Fix Applied:

Verify version shows VB30E_HF05 or later in application interface after patch installation.

📡 Detection & Monitoring

Log Indicators:

  • Unusual database queries from syngo.plaza application
  • SQL error messages in application logs
  • Multiple failed login attempts followed by database access

Network Indicators:

  • Unusual SQL traffic patterns to database servers
  • SQL queries with suspicious syntax from syngo.plaza systems

SIEM Query:

source="syngo.plaza" AND (sql_error OR sql_injection OR suspicious_query)

🔗 References

📤 Share & Export