CVE-2024-48416

8.8 HIGH

📋 TL;DR

This buffer overflow vulnerability in Edimax AC1200 routers allows attackers to execute arbitrary code by sending specially crafted requests to the web management interface. Attackers could potentially take full control of affected routers. All users of Edimax BR-6476AC routers with firmware version 1.06 are affected.

💻 Affected Systems

Products:
  • Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC
Versions: 1.06
Operating Systems: Embedded router firmware
Default Config Vulnerable: ⚠️ Yes
Notes: Vulnerability exists in default configuration. Router web interface must be accessible for exploitation.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete router compromise leading to persistent backdoor installation, network traffic interception, credential theft, and use as pivot point for attacking internal networks.

🟠

Likely Case

Router takeover enabling DNS hijacking, credential harvesting from connected devices, and botnet recruitment.

🟢

If Mitigated

Limited impact if router is behind firewall with restricted management interface access and regular monitoring.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: MEDIUM

Exploitation requires access to router management interface. No public exploit code available at time of analysis.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Check vendor for updated firmware

Vendor Advisory: http://edimax.com

Restart Required: Yes

Instructions:

1. Log into router web interface. 2. Navigate to firmware update section. 3. Download latest firmware from Edimax website. 4. Upload and apply firmware update. 5. Reboot router after update completes.

🔧 Temporary Workarounds

Disable Remote Management

all

Prevent external access to router web interface

Restrict Management Interface Access

all

Limit web interface access to trusted IP addresses only

🧯 If You Can't Patch

  • Replace vulnerable router with supported model
  • Place router behind firewall with strict inbound rules blocking management ports

🔍 How to Verify

Check if Vulnerable:

Check router firmware version in web interface under System Status or Administration section

Check Version:

Not applicable - check via web interface

Verify Fix Applied:

Verify firmware version is updated beyond 1.06 and test if /goform/fromSetLanDhcpsClientbinding endpoint behaves normally

📡 Detection & Monitoring

Log Indicators:

  • Multiple POST requests to /goform/fromSetLanDhcpsClientbinding with abnormal payload sizes
  • Router reboot events following suspicious requests

Network Indicators:

  • Unusual outbound connections from router
  • DNS queries to suspicious domains
  • Port scanning originating from router

SIEM Query:

source="router_logs" AND (uri="/goform/fromSetLanDhcpsClientbinding" AND content_length>1000)

🔗 References

📤 Share & Export