CVE-2024-46886

4.7 MEDIUM

📋 TL;DR

This vulnerability is an open redirect flaw in Siemens web servers where improper input validation allows attackers to redirect legitimate users to malicious URLs. Affected users must click a crafted link for exploitation to succeed. Siemens industrial control system devices with vulnerable web servers are impacted.

💻 Affected Systems

Products:
  • Siemens SIMATIC, SINUMERIK, SINAMICS products with affected web servers
Versions: Multiple versions across various product lines - see Siemens advisory for specific affected versions
Operating Systems: Embedded systems on industrial devices
Default Config Vulnerable: ⚠️ Yes
Notes: Specific affected products include SIMATIC S7-1500, SINUMERIK ONE, SINAMICS S210, and others. Check Siemens advisory for complete list.

⚠️ Manual Verification Required

This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.

Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).

🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.

Recommended Actions:
  1. Review the CVE details at NVD
  2. Check vendor security advisories for your specific version
  3. Test if the vulnerability is exploitable in your environment
  4. Consider updating to the latest version as a precaution

⚠️ Risk & Real-World Impact

🔴

Worst Case

Users could be redirected to phishing sites that steal credentials or deliver malware, potentially leading to full system compromise if combined with other vulnerabilities.

🟠

Likely Case

Phishing attacks where users are tricked into visiting malicious sites that steal session cookies or credentials.

🟢

If Mitigated

Limited impact with proper user awareness training and network segmentation preventing access to malicious external sites.

🌐 Internet-Facing: MEDIUM
🏢 Internal Only: LOW

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Exploitation requires user interaction (clicking a link) but no authentication. Attack complexity is low once a malicious link is crafted.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Varies by product - see Siemens advisory for specific fixed versions

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-876787.html

Restart Required: Yes

Instructions:

1. Review Siemens advisory SSA-876787. 2. Identify affected products in your environment. 3. Apply vendor-provided updates for each affected product. 4. Restart devices as required. 5. Verify fixes are applied.

🔧 Temporary Workarounds

Network segmentation

all

Isolate affected devices from untrusted networks and limit user access

User awareness training

all

Train users not to click suspicious links, especially in industrial control environments

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate affected devices from user networks
  • Deploy web application firewall rules to block redirect patterns and monitor for exploitation attempts

🔍 How to Verify

Check if Vulnerable:

Check device versions against Siemens advisory SSA-876787. Use Siemens TIA Portal or device web interfaces to verify versions.

Check Version:

Varies by device - typically through web interface or Siemens engineering tools

Verify Fix Applied:

Verify installed firmware/software versions match or exceed the patched versions listed in Siemens advisory.

📡 Detection & Monitoring

Log Indicators:

  • Unusual redirect patterns in web server logs
  • Multiple failed redirect attempts
  • Requests with suspicious URL parameters

Network Indicators:

  • HTTP redirects to external domains from industrial devices
  • Unusual outbound connections from ICS devices

SIEM Query:

source="web_server_logs" AND (url="*redirect=*" OR url="*url=*" OR url="*goto=*") AND dest_domain NOT IN (allowed_domains)

🔗 References

📤 Share & Export