CVE-2024-41629
📋 TL;DR
Texas Instruments Fusion Digital Power Designer v7.10.1 stores credentials in plaintext, allowing local attackers to read sensitive authentication information. This affects users of this specific version of the power management software. Attackers need local access to the system where the software is installed.
💻 Affected Systems
- Texas Instruments Fusion Digital Power Designer
📦 What is this software?
⚠️ Risk & Real-World Impact
Worst Case
Attackers obtain administrative credentials for power management systems, potentially gaining control over power infrastructure or using credentials for lateral movement.
Likely Case
Local users or malware with file system access can extract credentials stored in plaintext configuration files.
If Mitigated
With proper access controls and monitoring, credential theft can be detected and contained before misuse.
🎯 Exploit Status
Exploitation involves reading plaintext files, which is trivial for any user with file system access. The vulnerability disclosure includes technical details.
🛠️ Fix & Mitigation
✅ Official Fix
Patch Version: Unknown
Vendor Advisory: Not available
Restart Required: No
Instructions:
Check Texas Instruments website for security updates. No official patch information is available in the referenced disclosures.
🔧 Temporary Workarounds
Remove stored credentials
allConfigure the software to not store credentials or use credential-free authentication methods
Restrict file permissions
allSet strict file permissions on configuration files containing credentials
chmod 600 credential_files (Linux)
icacls credential_files /inheritance:r /grant:r "%USERNAME%":F (Windows)
🧯 If You Can't Patch
- Implement strict access controls to limit who can access systems running this software
- Monitor file access to credential storage locations and alert on unauthorized access attempts
🔍 How to Verify
Check if Vulnerable:
Check if Texas Instruments Fusion Digital Power Designer v7.10.1 is installed and examine configuration files for plaintext credentials
Check Version:
Check software version in application interface or installation directory
Verify Fix Applied:
Verify configuration files no longer contain plaintext credentials or have been secured with proper permissions
📡 Detection & Monitoring
Log Indicators:
- File access logs showing unauthorized users accessing configuration files
- Authentication attempts using credentials that match those stored in the software
Network Indicators:
- Unusual authentication patterns to power management systems
SIEM Query:
File access events where path contains 'Fusion Digital Power Designer' AND file extension in ('.cfg', '.ini', '.xml', '.json') AND user not in (authorized_users_list)