CVE-2024-41125

8.3 HIGH

📋 TL;DR

CVE-2024-41125 is an out-of-bounds read vulnerability in Contiki-NG's SNMP module that could allow attackers to read one byte of memory beyond an allocated buffer. This affects IoT devices running Contiki-NG with SNMP enabled, though SNMP is disabled by default. The vulnerability could potentially leak sensitive information or cause crashes.

💻 Affected Systems

Products:
  • Contiki-NG operating system
Versions: All versions prior to the patch in pull request #2936
Operating Systems: Contiki-NG
Default Config Vulnerable: ✅ No
Notes: Only vulnerable when SNMP module is explicitly enabled in build configuration. Default configuration has SNMP disabled.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Information disclosure of sensitive memory contents, potential system crash leading to denial of service, or as a stepping stone for further exploitation.

🟠

Likely Case

System crash or denial of service on affected IoT devices, potentially disrupting device functionality.

🟢

If Mitigated

No impact if SNMP is disabled (default configuration) or the patch is applied.

🌐 Internet-Facing: MEDIUM - IoT devices with SNMP exposed to the internet could be targeted, but SNMP is disabled by default.
🏢 Internal Only: LOW - Internal network exposure only reduces attack surface, but vulnerable devices could still be compromised from within the network.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Exploitation requires sending a specially crafted SNMP packet to a vulnerable device with SNMP enabled.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Patch available in pull request #2936, will be included in next Contiki-NG release

Vendor Advisory: https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-qjj3-gqx7-438w

Restart Required: Yes

Instructions:

1. Apply the patch from pull request #2936 manually. 2. Rebuild Contiki-NG with the patched source. 3. Deploy the updated firmware to affected devices. 4. Alternatively, wait for the next Contiki-NG release and update to that version.

🔧 Temporary Workarounds

Disable SNMP module

all

Disable the SNMP module in Contiki-NG build configuration to eliminate the vulnerability

Modify build configuration to set SNMP_CONF_ENABLED=0 or equivalent

🧯 If You Can't Patch

  • Disable SNMP functionality on all affected devices
  • Implement network segmentation to isolate devices with SNMP enabled from untrusted networks

🔍 How to Verify

Check if Vulnerable:

Check if SNMP is enabled in Contiki-NG build configuration and if the device is running a version without the patch from pull request #2936.

Check Version:

Check Contiki-NG version and build configuration for SNMP enablement

Verify Fix Applied:

Verify the patch from pull request #2936 is applied in the source code or that SNMP is disabled in the build configuration.

📡 Detection & Monitoring

Log Indicators:

  • Unexpected device crashes or restarts
  • SNMP-related error messages in device logs

Network Indicators:

  • Unusual SNMP traffic to IoT devices
  • SNMP packets with malformed length fields

SIEM Query:

Search for SNMP traffic to IoT device IPs followed by device crash/restart events

🔗 References

📤 Share & Export