CVE-2024-39251

10.0 CRITICAL

📋 TL;DR

This vulnerability in ThundeRobot Control Center allows attackers to send crafted IOCTL requests to the ControlCenter.sys/ControlCenter64.sys driver, potentially leading to information disclosure, arbitrary code execution, or privilege escalation. Users of ThundeRobot Control Center version 2.0.0.10 are affected, particularly those with the driver loaded.

💻 Affected Systems

Products:
  • ThundeRobot Control Center
Versions: v2.0.0.10
Operating Systems: Windows
Default Config Vulnerable: ⚠️ Yes
Notes: Requires the ControlCenter.sys (32-bit) or ControlCenter64.sys (64-bit) driver to be loaded and accessible.

⚠️ Manual Verification Required

This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.

Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).

🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.

Recommended Actions:
  1. Review the CVE details at NVD
  2. Check vendor security advisories for your specific version
  3. Test if the vulnerability is exploitable in your environment
  4. Consider updating to the latest version as a precaution

⚠️ Risk & Real-World Impact

🔴

Worst Case

Full system compromise with SYSTEM/root privileges, allowing complete control over the affected system, data theft, and lateral movement.

🟠

Likely Case

Local privilege escalation from a lower-privileged user to SYSTEM/administrator, enabling installation of malware, persistence mechanisms, or credential theft.

🟢

If Mitigated

Limited impact if driver is not loaded or access is restricted via security controls, though information disclosure may still occur.

🌐 Internet-Facing: LOW, as exploitation typically requires local access or ability to send IOCTL requests to the driver interface.
🏢 Internal Only: HIGH, as any user or process with access to the driver interface could exploit this vulnerability locally.

🎯 Exploit Status

Public PoC: ⚠️ Yes
Weaponized: LIKELY
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploitation requires ability to send IOCTL requests to the driver, which typically requires some level of local access. Public PoCs demonstrate privilege escalation.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Unknown

Vendor Advisory: Unknown

Restart Required: No

Instructions:

No official patch available. Monitor ThundeRobot vendor channels for updates. Consider workarounds or removal if possible.

🔧 Temporary Workarounds

Disable or Remove Driver

windows

Prevent loading of vulnerable ControlCenter.sys/ControlCenter64.sys driver

sc stop ControlCenter
sc delete ControlCenter
Remove driver files from system32\drivers

Restrict Driver Access

windows

Use security policies to restrict which users/processes can communicate with the driver

🧯 If You Can't Patch

  • Implement strict endpoint security controls to detect and block suspicious driver interactions
  • Segment networks to limit lateral movement potential if exploitation occurs

🔍 How to Verify

Check if Vulnerable:

Check if ControlCenter.sys or ControlCenter64.sys driver is loaded (sc query ControlCenter or driverquery | findstr ControlCenter). Verify ThundeRobot Control Center version is 2.0.0.10.

Check Version:

Check program version in Control Panel > Programs or examine installation directory for version information

Verify Fix Applied:

Confirm driver is not loaded or updated version is installed. Test with PoC to verify exploitation fails.

📡 Detection & Monitoring

Log Indicators:

  • Unusual IOCTL requests to ControlCenter driver
  • Privilege escalation events
  • Driver loading/unloading events

Network Indicators:

  • Local inter-process communication to driver interface

SIEM Query:

EventID=4688 OR EventID=4656 with process_name containing ControlCenter OR driver_name containing ControlCenter

🔗 References

📤 Share & Export