CVE-2024-0538

8.8 HIGH

📋 TL;DR

A critical stack-based buffer overflow vulnerability in Tenda W9 routers allows remote attackers to execute arbitrary code by manipulating the ssidIndex parameter in the formQosManage_auto function of the httpd component. This affects Tenda W9 routers running firmware version 1.0.0.7(4456). Attackers can exploit this without authentication to potentially take full control of affected devices.

💻 Affected Systems

Products:
  • Tenda W9
Versions: 1.0.0.7(4456)
Operating Systems: Embedded router firmware
Default Config Vulnerable: ⚠️ Yes
Notes: Affects the httpd component handling QoS management. The vulnerability is present in default configurations.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Remote code execution leading to complete device compromise, creation of persistent backdoors, network traffic interception, and lateral movement to other devices on the network.

🟠

Likely Case

Remote code execution allowing attackers to install malware, modify router settings, intercept network traffic, or use the device as part of a botnet.

🟢

If Mitigated

Limited impact if devices are behind firewalls with strict ingress filtering, though internal network compromise remains possible if exploited.

🌐 Internet-Facing: HIGH - The vulnerability is remotely exploitable and affects internet-facing routers with web management interfaces exposed.
🏢 Internal Only: HIGH - Even internally, the vulnerability can be exploited by attackers who gain initial access to the network.

🎯 Exploit Status

Public PoC: ⚠️ Yes
Weaponized: LIKELY
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Exploit details are publicly available in GitHub repositories. The vulnerability requires no authentication and has a straightforward exploitation path.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Unknown

Vendor Advisory: None available

Restart Required: Yes

Instructions:

1. Check Tenda's official website for firmware updates. 2. If an update is available, download the latest firmware. 3. Access router admin interface. 4. Navigate to System Tools > Firmware Upgrade. 5. Upload and install the new firmware. 6. Reboot the router.

🔧 Temporary Workarounds

Disable remote management

all

Prevent external access to the router's web management interface

Network segmentation

all

Isolate affected routers from critical network segments

🧯 If You Can't Patch

  • Replace affected Tenda W9 routers with devices from vendors that provide security updates
  • Implement strict network access controls to limit traffic to affected routers

🔍 How to Verify

Check if Vulnerable:

Check router firmware version via admin interface: System Status > Firmware Version. If version is 1.0.0.7(4456), the device is vulnerable.

Check Version:

No CLI command available. Must check through web interface at http://router_ip/

Verify Fix Applied:

Verify firmware version has been updated to a version later than 1.0.0.7(4456) through the admin interface.

📡 Detection & Monitoring

Log Indicators:

  • Unusual HTTP POST requests to formQosManage_auto endpoint
  • Large or malformed ssidIndex parameter values in HTTP requests
  • Router crash or restart logs

Network Indicators:

  • HTTP traffic to router management interface with abnormal parameter lengths
  • Exploit pattern matching from public PoCs

SIEM Query:

http.method:POST AND http.uri:"/goform/formQosManage_auto" AND (http.param.ssidIndex.length > 100 OR http.param.ssidIndex contains non-numeric characters)

🔗 References

📤 Share & Export