CVE-2023-5986

8.2 HIGH

📋 TL;DR

This vulnerability allows attackers to redirect users to malicious websites after successful login by manipulating URL parameters. It affects Schneider Electric software with web interfaces that don't properly validate redirect URLs. Users of affected Schneider Electric products are at risk.

💻 Affected Systems

Products:
  • Schneider Electric software with web interfaces (specific products not detailed in provided references)
Versions: Not specified in provided references
Operating Systems: Not specified
Default Config Vulnerable: ⚠️ Yes
Notes: Affects web applications that perform redirects after authentication without proper URL validation.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Attackers could redirect users to phishing sites that steal credentials or deliver malware, potentially leading to full system compromise.

🟠

Likely Case

Users are redirected to phishing pages that capture login credentials or personal information.

🟢

If Mitigated

With proper URL validation and user awareness, impact is limited to failed redirect attempts.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: LIKELY
Unauthenticated Exploit: ✅ No
Complexity: LOW

Requires user interaction (login) but exploitation is straightforward once the vulnerability is understood.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Not specified in provided references

Vendor Advisory: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf

Restart Required: Yes

Instructions:

1. Download the security update from Schneider Electric. 2. Apply the patch according to vendor instructions. 3. Restart affected services. 4. Verify the fix.

🔧 Temporary Workarounds

Implement URL validation

all

Add server-side validation to only allow redirects to trusted domains

Disable redirect functionality

all

Temporarily disable post-login redirects if not essential

🧯 If You Can't Patch

  • Implement web application firewall rules to block suspicious redirect patterns
  • Educate users to verify URLs before entering credentials

🔍 How to Verify

Check if Vulnerable:

Test if the application redirects to external URLs after login using manipulated parameters

Check Version:

Check software version through web interface or system commands specific to the Schneider Electric product

Verify Fix Applied:

Attempt the same redirect manipulation after patching to confirm it's blocked

📡 Detection & Monitoring

Log Indicators:

  • Unusual redirect patterns in web server logs
  • Multiple failed login attempts followed by redirects to external domains

Network Indicators:

  • HTTP 302/303 redirects to unexpected domains
  • Traffic to known phishing domains

SIEM Query:

web_redirect AND (external_domain OR suspicious_domain)

🔗 References

📤 Share & Export