CVE-2023-5391

9.8 CRITICAL

📋 TL;DR

This vulnerability allows remote code execution through deserialization of untrusted data in Schneider Electric products. Attackers can send specially crafted packets to execute arbitrary code on affected systems. Organizations using vulnerable Schneider Electric products are at risk.

💻 Affected Systems

Products:
  • Schneider Electric products (specific models not detailed in provided references)
Versions: Not specified in provided references
Operating Systems: Not specified - likely embedded systems running Schneider software
Default Config Vulnerable: ⚠️ Yes
Notes: The vulnerability affects Schneider Electric industrial control and automation products. Check vendor advisory for specific affected products.

📦 What is this software?

⚠️ Manual Verification Required

This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.

Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).

🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.

Recommended Actions:
  1. Review the CVE details at NVD
  2. Check vendor security advisories for your specific version
  3. Test if the vulnerability is exploitable in your environment
  4. Consider updating to the latest version as a precaution

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system compromise leading to data theft, ransomware deployment, or disruption of industrial operations

🟠

Likely Case

Unauthorized access to industrial control systems, data exfiltration, or lateral movement within OT networks

🟢

If Mitigated

Limited impact if network segmentation and proper access controls prevent exploitation attempts

🌐 Internet-Facing: HIGH - Directly exploitable via network packets without authentication
🏢 Internal Only: HIGH - Internal attackers or compromised systems can exploit this vulnerability

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

CVSS 9.8 indicates critical severity with low attack complexity. No authentication required for exploitation.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Not specified - check vendor advisory for specific versions

Vendor Advisory: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdf

Restart Required: Yes

Instructions:

1. Download and review Schneider Electric security advisory SEVD-2023-283-02. 2. Identify affected products in your environment. 3. Apply vendor-provided patches or firmware updates. 4. Restart affected systems as required. 5. Verify patch installation.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate affected systems from untrusted networks and implement strict firewall rules

Access Control Lists

all

Restrict network access to only trusted IP addresses and required protocols

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate vulnerable systems
  • Deploy intrusion detection systems to monitor for exploitation attempts

🔍 How to Verify

Check if Vulnerable:

Check product versions against Schneider Electric advisory SEVD-2023-283-02

Check Version:

Product-specific - consult device documentation or web interface

Verify Fix Applied:

Verify installed firmware/software version matches patched version in vendor advisory

📡 Detection & Monitoring

Log Indicators:

  • Unusual network connections to affected systems
  • Unexpected process execution
  • System crashes or abnormal behavior

Network Indicators:

  • Malformed packets sent to Schneider Electric product ports
  • Unexpected protocol traffic to industrial systems

SIEM Query:

source_ip IN (industrial_systems) AND (protocol_anomaly OR malformed_packet)