CVE-2023-49140

7.5 HIGH

📋 TL;DR

This vulnerability allows remote unauthenticated attackers to cause denial-of-service conditions in HMI GC-A2 series devices by sending specially crafted packets to specific ports. The commplex-link service becomes unresponsive, disrupting human-machine interface functionality. Organizations using affected HMI GC-A2 devices are at risk.

💻 Affected Systems

Products:
  • HMI GC-A2 series
Versions: All versions prior to the fix
Operating Systems: Embedded/Proprietary OS on HMI devices
Default Config Vulnerable: ⚠️ Yes
Notes: The commplex-link service runs on specific ports by default. Devices must be network-accessible to be vulnerable.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete service disruption of HMI GC-A2 devices, potentially affecting industrial control systems and manufacturing operations that rely on these interfaces.

🟠

Likely Case

Temporary service interruption requiring device restart, causing operational downtime in industrial environments.

🟢

If Mitigated

Minimal impact with proper network segmentation and monitoring in place to detect and block malicious traffic.

🌐 Internet-Facing: HIGH if devices are directly exposed to the internet, as exploitation requires no authentication.
🏢 Internal Only: MEDIUM as attackers would need internal network access, but exploitation remains simple and unauthenticated.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Exploitation requires sending crafted packets to specific ports, which is relatively simple for attackers with network access.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Check vendor advisory for specific firmware versions

Vendor Advisory: https://www.electronics.jtekt.co.jp/en/topics/202312116562/

Restart Required: Yes

Instructions:

1. Download latest firmware from JTEKT Electronics website. 2. Follow vendor's firmware update procedure for HMI GC-A2 devices. 3. Restart devices after update.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate HMI devices from untrusted networks using firewalls or VLANs

Port Blocking

all

Block access to the specific ports used by commplex-link service from untrusted sources

🧯 If You Can't Patch

  • Implement strict network access controls to limit which systems can communicate with HMI devices
  • Deploy network intrusion detection systems to monitor for DoS attack patterns targeting HMI ports

🔍 How to Verify

Check if Vulnerable:

Check device firmware version against vendor advisory. If running vulnerable version and commplex-link service is enabled, device is vulnerable.

Check Version:

Check device firmware version through HMI interface or vendor-specific management tools

Verify Fix Applied:

Verify firmware version matches patched version from vendor advisory and test service functionality.

📡 Detection & Monitoring

Log Indicators:

  • Unusual traffic spikes to HMI ports
  • Service restart events
  • Connection failures to commplex-link service

Network Indicators:

  • High volume of malformed packets to specific HMI ports
  • Traffic patterns matching DoS attack signatures

SIEM Query:

source_ip:external AND dest_port:[HMI_PORT_RANGE] AND packet_size:anomalous

🔗 References