CVE-2023-47207

9.8 CRITICAL

📋 TL;DR

This critical vulnerability in Delta Electronics InfraSuite Device Master allows unauthenticated attackers to execute arbitrary code with local administrator privileges. It affects version 1.0.7 of the software, which is used for industrial control system (ICS) device management. Organizations using this software for critical infrastructure are at significant risk.

💻 Affected Systems

Products:
  • Delta Electronics InfraSuite Device Master
Versions: 1.0.7
Operating Systems: Windows
Default Config Vulnerable: ⚠️ Yes
Notes: This is an ICS/SCADA system used in critical infrastructure environments. Default installations are vulnerable.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete compromise of industrial control systems, allowing attackers to disrupt critical infrastructure operations, manipulate industrial processes, or cause physical damage to equipment.

🟠

Likely Case

Attackers gain persistent access to ICS networks, deploy ransomware, steal sensitive industrial data, or establish footholds for lateral movement to other critical systems.

🟢

If Mitigated

Limited impact due to network segmentation and strict access controls, but still poses risk to isolated systems running vulnerable software.

🌐 Internet-Facing: HIGH
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: LIKELY
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

CISA has published an advisory indicating active exploitation is likely. The vulnerability requires no authentication and provides administrator privileges.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: 1.0.10

Vendor Advisory: https://www.deltaww.com/en-US/Service/SecurityAdvisory/Detail/2023-11-15

Restart Required: Yes

Instructions:

1. Download InfraSuite Device Master version 1.0.10 from Delta Electronics support portal. 2. Backup current configuration. 3. Stop all Device Master services. 4. Install the updated version. 5. Restart services and verify functionality.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate InfraSuite Device Master systems from untrusted networks and internet access

Firewall Restrictions

all

Implement strict firewall rules to limit access to Device Master services

🧯 If You Can't Patch

  • Immediately disconnect vulnerable systems from production networks
  • Implement application allowlisting and monitor for suspicious process execution

🔍 How to Verify

Check if Vulnerable:

Check the software version in the Device Master interface or installation directory. Version 1.0.7 is vulnerable.

Check Version:

Check the application's About dialog or installation properties

Verify Fix Applied:

Verify the software version shows 1.0.10 or later in the application interface.

📡 Detection & Monitoring

Log Indicators:

  • Unauthenticated access attempts to Device Master services
  • Unusual process execution from Device Master directories
  • Administrator privilege escalation events

Network Indicators:

  • Unusual outbound connections from Device Master systems
  • Traffic to known malicious IPs from ICS networks

SIEM Query:

source="device_master.log" AND (event_type="unauthorized_access" OR process_execution="suspicious")

🔗 References

📤 Share & Export