CVE-2023-46285

7.5 HIGH

📋 TL;DR

This vulnerability allows attackers to cause denial-of-service by sending specially crafted messages to port 4004/tcp on affected Siemens industrial software products. The service crashes but automatically restarts via watchdog. All users of affected Siemens Opcenter, SIMATIC, SINEC, and TIA Portal versions are impacted.

💻 Affected Systems

Products:
  • Opcenter Execution Foundation
  • Opcenter Quality
  • SIMATIC PCS neo
  • SINEC NMS
  • Totally Integrated Automation Portal (TIA Portal)
Versions: Opcenter Execution Foundation < V2407, Opcenter Quality < V2312, SIMATIC PCS neo < V4.1, SINEC NMS < V2.0 SP1, TIA Portal V14 all versions, TIA Portal V15.1 all versions, TIA Portal V16 all versions, TIA Portal V17 < V17 Update 8, TIA Portal V18 < V18 Update 3
Operating Systems: Windows-based industrial systems
Default Config Vulnerable: ⚠️ Yes
Notes: Port 4004/tcp must be accessible for exploitation; default configurations likely expose this port.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Persistent DoS attacks could disrupt industrial operations by repeatedly crashing critical services, potentially affecting production lines or quality control systems.

🟠

Likely Case

Temporary service disruption with automatic recovery, causing brief operational interruptions in industrial environments.

🟢

If Mitigated

Minimal impact with proper network segmentation and monitoring; service automatically recovers within watchdog timeout period.

🌐 Internet-Facing: HIGH if port 4004/tcp is exposed to untrusted networks, as exploitation requires no authentication.
🏢 Internal Only: MEDIUM as internal attackers could disrupt operations, but network segmentation reduces exposure.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Exploitation requires sending crafted packets to port 4004/tcp; no authentication needed.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Opcenter Execution Foundation V2407, Opcenter Quality V2312, SIMATIC PCS neo V4.1, SINEC NMS V2.0 SP1, TIA Portal V17 Update 8, TIA Portal V18 Update 3

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-999588.html

Restart Required: Yes

Instructions:

1. Download appropriate update from Siemens support portal. 2. Backup system configuration. 3. Apply update following Siemens documentation. 4. Restart affected services. 5. Verify version update.

🔧 Temporary Workarounds

Network Access Control

all

Restrict access to port 4004/tcp using firewall rules

Windows: netsh advfirewall firewall add rule name="Block Siemens 4004" dir=in action=block protocol=TCP localport=4004
Linux: iptables -A INPUT -p tcp --dport 4004 -j DROP

Service Port Change

windows

Change default port from 4004 to alternative port if supported

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate affected systems from untrusted networks
  • Deploy intrusion detection systems to monitor for crafted packets on port 4004/tcp

🔍 How to Verify

Check if Vulnerable:

Check installed version against affected versions list; verify port 4004/tcp is listening using netstat -an | findstr :4004 (Windows) or ss -tlnp | grep :4004 (Linux)

Check Version:

Check within each application's about/help menu or Siemens management console

Verify Fix Applied:

Confirm version is updated to patched version; test service stability with normal traffic

📡 Detection & Monitoring

Log Indicators:

  • Service crash and restart events in Windows Event Log or application logs
  • Watchdog restart messages

Network Indicators:

  • Unusual traffic patterns to port 4004/tcp
  • Crafted packets with specific patterns to port 4004

SIEM Query:

source_port=4004 AND (packet_size>threshold OR unusual_pattern)

🔗 References