CVE-2023-38584

9.8 CRITICAL

📋 TL;DR

This vulnerability in Weintek's cMT3000 HMI Web CGI device allows anonymous attackers to exploit a stack-based buffer overflow in the command_wb.cgi component. This could lead to control flow hijacking and login authentication bypass, affecting industrial control systems using these vulnerable HMI devices.

💻 Affected Systems

Products:
  • Weintek cMT3000 HMI
Versions: Specific versions not detailed in references, but all versions before security update are affected
Operating Systems: Embedded Linux-based HMI OS
Default Config Vulnerable: ⚠️ Yes
Notes: Affects the web CGI interface component specifically; devices with web access enabled are vulnerable.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete device compromise allowing remote code execution, unauthorized access to industrial control systems, and potential physical process manipulation.

🟠

Likely Case

Authentication bypass leading to unauthorized access to HMI interface and potential data exfiltration or configuration changes.

🟢

If Mitigated

Limited impact if devices are isolated behind firewalls with strict network segmentation and access controls.

🌐 Internet-Facing: HIGH - Web-accessible CGI interface with unauthenticated exploitation capability.
🏢 Internal Only: HIGH - Even internally, the vulnerability allows authentication bypass and potential lateral movement.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Stack-based buffer overflow with authentication bypass suggests relatively straightforward exploitation.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Security update referenced in TEC23005E document

Vendor Advisory: https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf

Restart Required: Yes

Instructions:

1. Download security update from Weintek website. 2. Apply firmware update following vendor instructions. 3. Restart device. 4. Verify web interface functionality.

🔧 Temporary Workarounds

Network Isolation

all

Disable external web access and isolate device on internal network

Configure firewall to block external access to port 80/443
Implement VLAN segmentation

CGI Disable

all

Disable CGI functionality if not required

Modify web server configuration to disable cgi-bin access

🧯 If You Can't Patch

  • Implement strict network segmentation and firewall rules to limit access to HMI devices
  • Deploy intrusion detection systems to monitor for buffer overflow attempts and authentication bypass patterns

🔍 How to Verify

Check if Vulnerable:

Check device firmware version against vendor advisory; test web CGI interface for command_wb.cgi endpoint

Check Version:

Check device web interface or serial console for firmware version information

Verify Fix Applied:

Verify firmware version matches patched version; test that authentication bypass is no longer possible

📡 Detection & Monitoring

Log Indicators:

  • Multiple failed authentication attempts followed by successful access
  • Unusual CGI command execution patterns
  • Buffer overflow error messages in web logs

Network Indicators:

  • HTTP requests to /cgi-bin/command_wb.cgi with oversized parameters
  • Unusual traffic patterns to HMI web interface

SIEM Query:

source="web_logs" AND (uri="/cgi-bin/command_wb.cgi" AND (param_size>threshold OR status=200 AFTER auth_failures))