CVE-2023-38527

7.8 HIGH

📋 TL;DR

This vulnerability allows remote code execution through specially crafted X_T files in Siemens Parasolid and Teamcenter Visualization software. An attacker can exploit an out-of-bounds read vulnerability to execute arbitrary code in the context of the current process. Affected users include those running vulnerable versions of Parasolid V34.1, V35.0, and Teamcenter Visualization V14.1, V14.2, V14.3, and V2312.

💻 Affected Systems

Products:
  • Parasolid V34.1
  • Parasolid V35.0
  • Teamcenter Visualization V14.1
  • Teamcenter Visualization V14.2
  • Teamcenter Visualization V14.3
  • Teamcenter Visualization V2312
Versions: Parasolid V34.1 < V34.1.258, Parasolid V35.0 < V35.0.254, Teamcenter Visualization V14.1 (all versions), V14.2 < V14.2.0.12, V14.3 < V14.3.0.9, V2312 < V2312.0004
Operating Systems: Windows, Linux
Default Config Vulnerable: ⚠️ Yes
Notes: All default configurations are vulnerable when processing X_T files.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system compromise with attacker gaining the same privileges as the application process, potentially leading to data theft, system manipulation, or lateral movement.

🟠

Likely Case

Application crash or denial of service, with potential for arbitrary code execution if the attacker can control memory layout.

🟢

If Mitigated

Application crash without code execution if memory protections (ASLR, DEP) are effective.

🌐 Internet-Facing: MEDIUM - Requires user to open malicious X_T file, but could be delivered via email or web download.
🏢 Internal Only: MEDIUM - Internal users could be tricked into opening malicious files, but requires user interaction.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: MEDIUM

Exploitation requires user to open a malicious X_T file. No authentication is needed beyond file access.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Parasolid V34.1.258, V35.0.254; Teamcenter Visualization V14.2.0.12, V14.3.0.9, V2312.0004

Vendor Advisory: https://cert-portal.siemens.com/productcert/html/ssa-407785.html

Restart Required: Yes

Instructions:

1. Download patches from Siemens support portal. 2. Apply patches according to vendor documentation. 3. Restart affected applications. 4. Verify version updates.

🔧 Temporary Workarounds

Restrict X_T file processing

all

Block or restrict processing of X_T files from untrusted sources

Application sandboxing

all

Run vulnerable applications with reduced privileges or in sandboxed environments

🧯 If You Can't Patch

  • Implement strict file validation for X_T files from untrusted sources
  • Use application allowlisting to prevent unauthorized execution of vulnerable software

🔍 How to Verify

Check if Vulnerable:

Check application version against affected versions list. If using vulnerable version and processing X_T files, system is vulnerable.

Check Version:

Check version through application interface or consult vendor documentation for version query commands.

Verify Fix Applied:

Verify application version matches patched versions: Parasolid V34.1.258+, V35.0.254+; Teamcenter Visualization V14.2.0.12+, V14.3.0.9+, V2312.0004+

📡 Detection & Monitoring

Log Indicators:

  • Application crashes when processing X_T files
  • Unexpected process termination
  • Memory access violation errors

Network Indicators:

  • Downloads of X_T files from untrusted sources
  • File transfers to vulnerable systems

SIEM Query:

Process: ("parasolid.exe" OR "teamcenter*.exe") AND EventID: 1000 (Application Crash)

🔗 References

📤 Share & Export