CVE-2023-30898

9.9 CRITICAL

📋 TL;DR

This CVE describes a critical deserialization vulnerability in Siemens Siveillance Video Event Server that allows authenticated remote attackers to execute arbitrary code on affected systems. The vulnerability affects multiple versions of Siveillance Video 2020-2023. With a CVSS score of 9.9, this represents a severe security risk requiring immediate attention.

💻 Affected Systems

Products:
  • Siveillance Video
Versions: 2020 R2 (< V20.2 HotfixRev14), 2020 R3 (< V20.3 HotfixRev12), 2021 R1 (< V21.1 HotfixRev12), 2021 R2 (< V21.2 HotfixRev8), 2022 R1 (< V22.1 HotfixRev7), 2022 R2 (< V22.2 HotfixRev5), 2022 R3 (< V22.3 HotfixRev2), 2023 R1 (< V23.1 HotfixRev1)
Operating Systems: Windows
Default Config Vulnerable: ⚠️ Yes
Notes: Affects the Event Server component specifically. Requires authenticated access to exploit.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Full system compromise allowing attacker to execute arbitrary code with system privileges, potentially leading to complete control of the surveillance system, data exfiltration, or lateral movement within the network.

🟠

Likely Case

Authenticated attacker gains remote code execution on the Event Server, enabling them to disrupt surveillance operations, access video feeds, or use the system as a foothold for further attacks.

🟢

If Mitigated

With proper network segmentation and authentication controls, impact is limited to the isolated surveillance network segment, preventing lateral movement to critical systems.

🌐 Internet-Facing: HIGH
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploitation requires authenticated access but deserialization vulnerabilities are often easily weaponized once details are known.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: 2020 R2: V20.2 HotfixRev14, 2020 R3: V20.3 HotfixRev12, 2021 R1: V21.1 HotfixRev12, 2021 R2: V21.2 HotfixRev8, 2022 R1: V22.1 HotfixRev7, 2022 R2: V22.2 HotfixRev5, 2022 R3: V22.3 HotfixRev2, 2023 R1: V23.1 HotfixRev1

Vendor Advisory: https://cert-portal.siemens.com/productcert/pdf/ssa-789345.pdf

Restart Required: Yes

Instructions:

1. Download appropriate hotfix from Siemens support portal. 2. Backup system configuration. 3. Apply hotfix following Siemens installation guide. 4. Restart Event Server service. 5. Verify successful update.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate Siveillance Video systems from general network and internet access

Authentication Hardening

all

Implement strong authentication controls and limit user access to Event Server

🧯 If You Can't Patch

  • Segment the surveillance network completely from other systems
  • Implement strict firewall rules to limit access to Event Server ports

🔍 How to Verify

Check if Vulnerable:

Check Siveillance Video version against affected versions list in SSA-789345

Check Version:

Check version in Siveillance Video Management Client or Windows Programs and Features

Verify Fix Applied:

Verify installed version matches or exceeds the patched versions listed in the advisory

📡 Detection & Monitoring

Log Indicators:

  • Unusual authentication attempts to Event Server
  • Unexpected process creation from Event Server service
  • Deserialization errors in application logs

Network Indicators:

  • Unusual network connections from Event Server to external systems
  • Suspicious traffic patterns to Event Server ports

SIEM Query:

source="siveillance" AND (event_type="deserialization_error" OR process_name="powershell.exe" OR cmd.exe) FROM EventServer

🔗 References