CVE-2023-0839

9.8 CRITICAL

📋 TL;DR

This vulnerability in ProMIS Process Co. inSCADA allows attackers to perform account footprinting by exploiting improper protection of outbound error messages and alert signals. It affects inSCADA systems before version 20230115-1, potentially exposing user account information to unauthorized parties.

💻 Affected Systems

Products:
  • ProMIS Process Co. inSCADA
Versions: All versions before 20230115-1
Operating Systems: Unknown - likely embedded/industrial OS
Default Config Vulnerable: ⚠️ Yes
Notes: Affects inSCADA systems specifically; exact OS dependencies not specified in available references.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Attackers could enumerate all valid user accounts, enabling targeted credential attacks, privilege escalation, or lateral movement within SCADA/ICS environments.

🟠

Likely Case

Information disclosure allowing attackers to identify valid user accounts for subsequent brute-force or credential stuffing attacks.

🟢

If Mitigated

Limited information leakage with proper network segmentation and access controls preventing external attackers from reaching vulnerable interfaces.

🌐 Internet-Facing: HIGH - SCADA systems exposed to internet could allow remote attackers to enumerate accounts without authentication.
🏢 Internal Only: MEDIUM - Internal attackers could still exploit this for reconnaissance and privilege escalation within the network.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Based on CWE-1320 description, exploitation likely involves analyzing error responses to determine valid account information.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: 20230115-1

Vendor Advisory: https://www.usom.gov.tr/bildirim/tr-23-0127

Restart Required: Yes

Instructions:

1. Contact ProMIS Process Co. for patch 20230115-1. 2. Apply patch following vendor instructions. 3. Restart affected inSCADA systems. 4. Verify patch installation.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate inSCADA systems from untrusted networks to prevent external exploitation.

Access Control Restrictions

all

Implement strict firewall rules to limit access to inSCADA interfaces only to authorized IP addresses.

🧯 If You Can't Patch

  • Implement network segmentation to isolate inSCADA systems from untrusted networks
  • Deploy intrusion detection systems to monitor for account enumeration attempts

🔍 How to Verify

Check if Vulnerable:

Check inSCADA version; if earlier than 20230115-1, system is vulnerable. Test by sending malformed requests and observing if error responses leak account information.

Check Version:

Check via inSCADA administrative interface or consult vendor documentation for version query method.

Verify Fix Applied:

Verify version is 20230115-1 or later. Test that error responses no longer disclose account-related information.

📡 Detection & Monitoring

Log Indicators:

  • Multiple failed authentication attempts with varying usernames
  • Unusual error messages in application logs indicating account validation responses

Network Indicators:

  • Repeated requests to authentication endpoints with different parameters
  • Abnormal traffic patterns to SCADA interfaces

SIEM Query:

source="inscada" AND (event_type="authentication_error" OR message="*account*" OR message="*user*") | stats count by src_ip