CVE-2022-45792

7.8 HIGH

📋 TL;DR

This vulnerability in Omron PLC engineering software allows attackers to craft malicious project files that exploit directory traversal to write arbitrary files on the filesystem. Attackers can overwrite existing files or create new ones with the privileges of the logged-in user. This affects users of Omron PLC programming and configuration software.

💻 Affected Systems

Products:
  • Omron PLC programming and engineering software (specific product names not provided in reference)
Versions: Not specified in provided reference
Operating Systems: Windows (assumed based on industrial control software typical deployment)
Default Config Vulnerable: ⚠️ Yes
Notes: Affects software used to program and configure Omron programmable logic controllers. Requires user to open a malicious project file.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system compromise through arbitrary file write leading to privilege escalation, remote code execution, or destruction of critical system files.

🟠

Likely Case

Local file corruption, data loss, or malware deployment through malicious project files.

🟢

If Mitigated

Limited impact if software runs with minimal privileges and project files are from trusted sources only.

🌐 Internet-Facing: LOW - This requires local access or file transfer to the target system.
🏢 Internal Only: HIGH - Malicious project files can be introduced through USB drives, network shares, or compromised engineering workstations.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploitation requires user interaction to open malicious project file. No authentication bypass needed if user has file access.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Not specified in provided reference

Vendor Advisory: https://www.dragos.com/advisory/omron-plc-and-engineering-software-network-and-file-format-access/

Restart Required: Yes

Instructions:

1. Contact Omron for specific patch information. 2. Apply vendor-provided updates to affected software. 3. Restart systems as required by patch.

🔧 Temporary Workarounds

Restrict project file sources

all

Only open project files from trusted, verified sources. Implement strict controls on file transfers to engineering workstations.

Run with minimal privileges

windows

Configure software to run with limited user privileges rather than administrative rights.

🧯 If You Can't Patch

  • Isolate engineering workstations from general network access and internet
  • Implement application whitelisting to prevent execution of unauthorized files

🔍 How to Verify

Check if Vulnerable:

Check software version against vendor advisory. If using unpatched Omron PLC engineering software, assume vulnerable.

Check Version:

Check software 'About' dialog or vendor documentation for version information

Verify Fix Applied:

Verify software has been updated to patched version specified by vendor.

📡 Detection & Monitoring

Log Indicators:

  • Unexpected file writes in system directories
  • Multiple failed file access attempts from engineering software

Network Indicators:

  • Unusual file transfers to engineering workstations
  • Project files from untrusted sources

SIEM Query:

Process:omron_software AND (FileCreate:*\..\* OR FileWrite:*\..\*)

🔗 References