CVE-2022-29561

7.5 HIGH

📋 TL;DR

This CVE describes a Cross-Site Request Forgery (CSRF) vulnerability in Siemens RUGGEDCOM ROX industrial routers. An attacker can trick authenticated users into clicking malicious links that perform unauthorized actions on the device. All RUGGEDCOM ROX MX and RX series devices running firmware versions below V2.16.0 are affected.

💻 Affected Systems

Products:
  • RUGGEDCOM ROX MX5000
  • RUGGEDCOM ROX MX5000RE
  • RUGGEDCOM ROX RX1400
  • RUGGEDCOM ROX RX1500
  • RUGGEDCOM ROX RX1501
  • RUGGEDCOM ROX RX1510
  • RUGGEDCOM ROX RX1511
  • RUGGEDCOM ROX RX1512
  • RUGGEDCOM ROX RX1524
  • RUGGEDCOM ROX RX1536
  • RUGGEDCOM ROX RX5000
Versions: All versions < V2.16.0
Operating Systems: RUGGEDCOM ROX firmware
Default Config Vulnerable: ⚠️ Yes
Notes: All affected devices with web interface enabled are vulnerable. The vulnerability requires an authenticated user session to be exploited.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

An attacker could gain full administrative control of the industrial router, potentially disrupting critical infrastructure operations, modifying network configurations, or using the device as an entry point into industrial control systems.

🟠

Likely Case

Attackers could modify device settings, change network configurations, or disrupt communications in industrial environments by tricking authenticated administrators into clicking malicious links.

🟢

If Mitigated

With proper network segmentation and user awareness training, the impact is limited to potential configuration changes that would require physical access or additional exploitation to cause significant harm.

🌐 Internet-Facing: HIGH
🏢 Internal Only: MEDIUM

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploitation requires social engineering to trick authenticated users into clicking malicious links. No authentication bypass is needed as the attack leverages existing authenticated sessions.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: V2.16.0 or later

Vendor Advisory: https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf

Restart Required: Yes

Instructions:

1. Download firmware V2.16.0 or later from Siemens support portal. 2. Backup current configuration. 3. Upload and install the new firmware via the web interface or CLI. 4. Reboot the device. 5. Verify the firmware version after reboot.

🔧 Temporary Workarounds

Implement CSRF Tokens

all

Add anti-CSRF tokens to web forms if custom web applications are running on the device

Network Segmentation

all

Isolate RUGGEDCOM devices in separate network segments with strict access controls

🧯 If You Can't Patch

  • Implement strict network segmentation to limit access to RUGGEDCOM web interfaces
  • Train users to avoid clicking unknown links while authenticated to industrial devices

🔍 How to Verify

Check if Vulnerable:

Check firmware version via web interface (System > About) or CLI using 'show version' command

Check Version:

show version

Verify Fix Applied:

Verify firmware version is V2.16.0 or higher and test web interface functionality

📡 Detection & Monitoring

Log Indicators:

  • Multiple configuration changes from same IP in short timeframe
  • Unusual administrative actions from unexpected user sessions

Network Indicators:

  • HTTP requests with suspicious referer headers
  • Multiple POST requests to administrative endpoints from external sources

SIEM Query:

source="rugcom*" AND (action="config_change" OR action="admin_action") AND count() > threshold

🔗 References

📤 Share & Export