CVE-2022-25752

9.8 CRITICAL

📋 TL;DR

This vulnerability affects Siemens SCALANCE industrial network switches. It allows unauthenticated remote attackers to brute-force session IDs and hijack existing administrative sessions due to insecure calculation of session IDs and nonces in the web server.

💻 Affected Systems

Products:
  • SCALANCE X302-7 EEC
  • SCALANCE X304-2FE
  • SCALANCE X306-1LD FE
  • SCALANCE X307-2 EEC
  • SCALANCE X307-3
  • SCALANCE X307-3LD
  • SCALANCE X308-2
  • SCALANCE X308-2LD
  • SCALANCE X308-2LH
  • SCALANCE X308-2LH+
  • SCALANCE X308-2M
  • SCALANCE X308-2M PoE
  • SCALANCE X308-2M TS
  • SCALANCE X310
  • SCALANCE X310FE
  • SCALANCE X320-1 FE
  • SCALANCE X320-1-2LD FE
  • SCALANCE X408-2
  • SCALANCE XR324-12M
  • SCALANCE XR324-12M TS
  • SCALANCE XR324-4M EEC
  • SCALANCE XR324-4M PoE
  • SIPLUS NET SCALANCE X308-2
Versions: All versions prior to V4.1
Operating Systems: Embedded firmware
Default Config Vulnerable: ⚠️ Yes
Notes: All listed SCALANCE switch models with web interface enabled are vulnerable by default.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete compromise of network infrastructure, allowing attacker to reconfigure switches, disrupt industrial operations, or pivot to other systems.

🟠

Likely Case

Unauthorized administrative access to switches, enabling network configuration changes, traffic interception, or denial of service.

🟢

If Mitigated

Limited impact if switches are isolated from untrusted networks and have strong access controls.

🌐 Internet-Facing: HIGH - Directly exploitable over network without authentication.
🏢 Internal Only: HIGH - Even internally, any network-accessible device is vulnerable to session hijacking.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

The vulnerability description indicates brute-forcing is possible, suggesting relatively straightforward exploitation.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: V4.1 or later

Vendor Advisory: https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf

Restart Required: Yes

Instructions:

1. Download firmware V4.1 or later from Siemens support portal. 2. Backup current configuration. 3. Upload new firmware via web interface or management tools. 4. Reboot device. 5. Restore configuration if needed.

🔧 Temporary Workarounds

Disable web interface

all

Disable the vulnerable web server interface to prevent remote exploitation.

Configure via CLI: no ip http server
Or via web interface: disable HTTP/HTTPS services

Network segmentation

all

Restrict access to switch management interfaces to trusted networks only.

Configure ACLs: access-list 1 permit trusted_network
Apply to management interface

🧯 If You Can't Patch

  • Isolate affected switches in dedicated VLANs with strict firewall rules
  • Implement multi-factor authentication for management access if supported

🔍 How to Verify

Check if Vulnerable:

Check firmware version via web interface or CLI command: show version

Check Version:

show version

Verify Fix Applied:

Confirm firmware version is V4.1 or higher using show version command

📡 Detection & Monitoring

Log Indicators:

  • Multiple failed login attempts followed by successful login from different IP
  • Unusual configuration changes from unexpected sources

Network Indicators:

  • Brute-force patterns to switch web interface
  • Management traffic from unauthorized networks

SIEM Query:

source_ip=switch_management_interface AND (event_type=authentication_failure > 10 within 1min OR event_type=configuration_change)

🔗 References

📤 Share & Export