CVE-2022-1375

9.8 CRITICAL

📋 TL;DR

Delta Electronics DIAEnergie versions prior to 1.8.02.004 contain a blind SQL injection vulnerability in the DIAE_slogHandler.ashx endpoint. This allows attackers to execute arbitrary SQL queries, potentially leading to data theft, system compromise, and remote code execution. Organizations using DIAEnergie for industrial energy management are affected.

💻 Affected Systems

Products:
  • Delta Electronics DIAEnergie
Versions: All versions prior to 1.8.02.004
Operating Systems: Windows
Default Config Vulnerable: ⚠️ Yes
Notes: DIAEnergie is typically deployed on Windows systems in industrial environments for energy management and monitoring.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Full system compromise: attacker gains administrative access, exfiltrates sensitive industrial data, executes arbitrary system commands, and potentially disrupts industrial operations.

🟠

Likely Case

Database compromise: attacker extracts credentials, configuration data, and operational information, then pivots to other systems in the network.

🟢

If Mitigated

Limited impact: proper network segmentation and input validation prevent successful exploitation, limiting damage to isolated systems.

🌐 Internet-Facing: HIGH
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: LIKELY
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

SQL injection vulnerabilities are commonly exploited with readily available tools. The blind nature requires more effort but is still highly exploitable.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: 1.8.02.004

Vendor Advisory: https://www.deltaww.com/en-US/products/Industrial_Automation/Industrial_Software/DIAEnergie/Overview/

Restart Required: Yes

Instructions:

1. Download DIAEnergie version 1.8.02.004 from Delta Electronics. 2. Backup current configuration and data. 3. Install the update following vendor instructions. 4. Restart the DIAEnergie service and verify functionality.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate DIAEnergie systems from untrusted networks and internet access

Web Application Firewall

all

Deploy WAF with SQL injection protection rules

🧯 If You Can't Patch

  • Implement strict network access controls to limit connections to DIAEnergie systems
  • Monitor for unusual database queries and web requests to the vulnerable endpoint

🔍 How to Verify

Check if Vulnerable:

Check DIAEnergie version in application interface or installation directory. Versions below 1.8.02.004 are vulnerable.

Check Version:

Check DIAEnergie application interface or installation properties

Verify Fix Applied:

Confirm version is 1.8.02.004 or higher in application interface. Test that DIAE_slogHandler.ashx endpoint properly validates input.

📡 Detection & Monitoring

Log Indicators:

  • Unusual SQL queries in database logs
  • Multiple requests to DIAE_slogHandler.ashx with SQL-like parameters
  • Failed authentication attempts followed by SQL injection patterns

Network Indicators:

  • HTTP requests containing SQL keywords (SELECT, UNION, etc.) to DIAE_slogHandler.ashx
  • Unusual outbound connections from DIAEnergie server

SIEM Query:

source="web_server" AND uri="*DIAE_slogHandler.ashx*" AND (param="*SELECT*" OR param="*UNION*" OR param="*OR 1=1*")

🔗 References

📤 Share & Export