CVE-2021-44544

7.5 HIGH

📋 TL;DR

DIAEnergie versions 1.7.5 and earlier contain a cross-site scripting (XSS) vulnerability in the 'name' parameter of HandlerEnergyType.ashx. This allows attackers to inject malicious scripts that execute in users' browsers when viewing affected pages. Organizations using DIAEnergie for industrial energy management are affected.

💻 Affected Systems

Products:
  • DIAEnergie
Versions: Version 1.7.5 and earlier
Operating Systems: Windows (typically)
Default Config Vulnerable: ⚠️ Yes
Notes: DIAEnergie is an industrial energy management system used in critical infrastructure sectors.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Attackers could steal session cookies, perform actions as authenticated users, redirect to malicious sites, or install malware on user systems.

🟠

Likely Case

Session hijacking, credential theft, or defacement of the application interface.

🟢

If Mitigated

Limited impact if input validation and output encoding are properly implemented.

🌐 Internet-Facing: HIGH if DIAEnergie is exposed to the internet, as XSS can be exploited remotely.
🏢 Internal Only: MEDIUM if only accessible internally, but still exploitable by malicious insiders or compromised internal systems.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ✅ No
Complexity: LOW

XSS vulnerabilities typically require user interaction (visiting a malicious link) but are straightforward to exploit.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Version 1.7.6 or later

Vendor Advisory: https://www.cisa.gov/uscert/ics/advisories/icsa-21-238-03

Restart Required: Yes

Instructions:

1. Download DIAEnergie version 1.7.6 or later from the vendor. 2. Backup current installation and data. 3. Install the updated version following vendor documentation. 4. Restart the DIAEnergie service and verify functionality.

🔧 Temporary Workarounds

Input Validation Filter

all

Implement server-side input validation to sanitize the 'name' parameter in HandlerEnergyType.ashx.

Modify HandlerEnergyType.ashx to validate/sanitize input using regex: [a-zA-Z0-9\s_-]+

Web Application Firewall (WAF)

all

Deploy a WAF with XSS protection rules to block malicious requests.

🧯 If You Can't Patch

  • Isolate DIAEnergie system on a segmented network with strict access controls.
  • Implement Content Security Policy (CSP) headers to restrict script execution sources.

🔍 How to Verify

Check if Vulnerable:

Test by injecting a simple XSS payload like <script>alert('test')</script> into the 'name' parameter of HandlerEnergyType.ashx and check if it executes.

Check Version:

Check the DIAEnergie interface or configuration files for version information (typically in web interface footer or about page).

Verify Fix Applied:

After patching, repeat the XSS test; the script should be sanitized or blocked. Check the application version.

📡 Detection & Monitoring

Log Indicators:

  • Unusual or malformed 'name' parameter values in HandlerEnergyType.ashx requests in web server logs.

Network Indicators:

  • HTTP requests to HandlerEnergyType.ashx containing script tags or JavaScript in parameters.

SIEM Query:

source="web_logs" AND uri="*HandlerEnergyType.ashx*" AND (param="*<script>*" OR param="*javascript:*")

🔗 References

📤 Share & Export