CVE-2021-38389

9.8 CRITICAL

📋 TL;DR

This vulnerability allows remote attackers to execute arbitrary code on Advantech WebAccess systems by exploiting a stack-based buffer overflow. Attackers can potentially take full control of affected systems. Organizations using Advantech WebAccess versions 9.02 and prior are affected.

💻 Affected Systems

Products:
  • Advantech WebAccess
Versions: 9.02 and all prior versions
Operating Systems: Windows (typically Windows Server 2008/2012/2016)
Default Config Vulnerable: ⚠️ Yes
Notes: WebAccess is SCADA/HMI software used in industrial environments; default installations are vulnerable

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system compromise leading to data theft, ransomware deployment, or lateral movement within industrial control networks

🟠

Likely Case

Remote code execution allowing attackers to install malware, create backdoors, or disrupt industrial operations

🟢

If Mitigated

Limited impact if systems are isolated, patched, or have exploit mitigations like DEP/ASLR enabled

🌐 Internet-Facing: HIGH - CVSS 9.8 indicates critical risk for internet-exposed systems
🏢 Internal Only: HIGH - Buffer overflow vulnerabilities can be exploited from internal networks

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: LIKELY
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Stack-based buffer overflows are well-understood attack vectors; CISA advisory suggests active exploitation is possible

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: 9.02.20211018 or later

Vendor Advisory: https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02

Restart Required: Yes

Instructions:

1. Download patch from Advantech support portal. 2. Backup configuration and data. 3. Stop WebAccess services. 4. Apply patch. 5. Restart services and verify functionality.

🔧 Temporary Workarounds

Network Segmentation

all

Isolate WebAccess systems from untrusted networks and internet

Windows Exploit Protection

windows

Enable Data Execution Prevention (DEP) and Address Space Layout Randomization (ASLR)

bcdedit /set {current} nx AlwaysOn
reg add "HKLM\SYSTEM\CurrentControlSet\Control\Session Manager\Memory Management" /v MoveImages /t REG_DWORD /d 0xffffffff

🧯 If You Can't Patch

  • Implement strict network access controls and firewall rules to limit connections to WebAccess
  • Deploy intrusion detection/prevention systems with rules for buffer overflow attempts

🔍 How to Verify

Check if Vulnerable:

Check WebAccess version in About dialog or registry: HKEY_LOCAL_MACHINE\SOFTWARE\Advantech\WebAccess\Node\Version

Check Version:

reg query "HKLM\SOFTWARE\Advantech\WebAccess\Node" /v Version

Verify Fix Applied:

Verify version is 9.02.20211018 or later and check patch installation logs

📡 Detection & Monitoring

Log Indicators:

  • Unusual process creation from WebAccess executables
  • Buffer overflow patterns in application logs
  • Failed authentication attempts followed by large data transfers

Network Indicators:

  • Unusual traffic patterns to WebAccess ports (typically 80/443/4592)
  • Large payloads sent to WebAccess services
  • Exploit kit signatures in network traffic

SIEM Query:

source="webaccess" AND (event_id=4688 OR process_name="cmd.exe" OR process_name="powershell.exe")

🔗 References