CVE-2021-32971

7.5 HIGH

📋 TL;DR

A null pointer dereference vulnerability in the SuiteLink server allows attackers to cause denial of service by sending a specially crafted command 0x07. This affects industrial control systems using vulnerable versions of AVEVA's SuiteLink server software, potentially disrupting critical operations.

💻 Affected Systems

Products:
  • AVEVA SuiteLink Server
Versions: All versions prior to 4.0.0.0
Operating Systems: Windows
Default Config Vulnerable: ⚠️ Yes
Notes: SuiteLink is commonly used in industrial control systems for OPC UA communications between SCADA/HMI and PLCs.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete denial of service causing SuiteLink server crash, disrupting industrial control system communications and potentially halting operations.

🟠

Likely Case

Service disruption requiring server restart, causing temporary loss of connectivity between industrial control system components.

🟢

If Mitigated

Limited impact with proper network segmentation and monitoring allowing quick detection and recovery.

🌐 Internet-Facing: HIGH if SuiteLink servers are exposed to untrusted networks, as exploitation requires only network access.
🏢 Internal Only: MEDIUM as internal attackers or malware could still exploit this to disrupt operations.

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: UNKNOWN
Unauthenticated Exploit: ⚠️ Yes
Complexity: LOW

Exploitation requires sending malformed command 0x07 to the SuiteLink server port (typically 1211/TCP). No authentication required.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: 4.0.0.0 and later

Vendor Advisory: https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-003.pdf

Restart Required: Yes

Instructions:

1. Download SuiteLink Server version 4.0.0.0 or later from AVEVA support portal. 2. Stop the SuiteLink service. 3. Install the updated version. 4. Restart the service.

🔧 Temporary Workarounds

Network Segmentation

all

Restrict access to SuiteLink server port (1211/TCP) to only trusted industrial control system components.

firewall-cmd --permanent --add-rich-rule='rule family="ipv4" source address="TRUSTED_IP_RANGE" port protocol="tcp" port="1211" accept'
netsh advfirewall firewall add rule name="SuiteLink Restrict" dir=in action=allow protocol=TCP localport=1211 remoteip=TRUSTED_IP_RANGE

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate SuiteLink servers from untrusted networks
  • Deploy network monitoring and intrusion detection for traffic on port 1211/TCP

🔍 How to Verify

Check if Vulnerable:

Check SuiteLink Server version via Windows Programs and Features or by examining installed software version. Versions below 4.0.0.0 are vulnerable.

Check Version:

wmic product where name="AVEVA SuiteLink Server" get version

Verify Fix Applied:

Confirm SuiteLink Server version is 4.0.0.0 or higher and verify service is running normally after patch.

📡 Detection & Monitoring

Log Indicators:

  • SuiteLink service crash events in Windows Event Log
  • Unexpected service restarts

Network Indicators:

  • Traffic to port 1211/TCP containing command 0x07 from untrusted sources
  • Sudden cessation of normal SuiteLink communications

SIEM Query:

source="windows" AND (event_id=7034 OR event_id=1000) AND process_name="SuiteLink*"

🔗 References

📤 Share & Export