CVE-2021-28154

9.1 CRITICAL

📋 TL;DR

CVE-2021-28154 is a high-severity vulnerability in Camunda Modeler that allows arbitrary file read/write access through a crafted IPC message. Attackers can exploit the exposed ipcRenderer interface to manipulate file operations. This affects all users of Camunda Modeler versions through 4.6.0.

💻 Affected Systems

Products:
  • Camunda Modeler (camunda-modeler)
Versions: through 4.6.0
Operating Systems: Windows, macOS, Linux
Default Config Vulnerable: ⚠️ Yes
Notes: All default installations are vulnerable. The vendor's security claims about remote script restrictions do not prevent this local IPC exploitation.

📦 What is this software?

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system compromise through arbitrary file write leading to remote code execution, data theft, or ransomware deployment.

🟠

Likely Case

Local file system manipulation including reading sensitive files, writing malicious scripts, or tampering with configuration files.

🟢

If Mitigated

Limited impact if application is isolated and runs with minimal privileges, though file access remains possible.

🌐 Internet-Facing: LOW - The vulnerability requires local access or social engineering to trigger malicious IPC messages.
🏢 Internal Only: HIGH - Internal attackers or compromised internal systems can exploit this to escalate privileges and access sensitive files.

🎯 Exploit Status

Public PoC: ⚠️ Yes
Weaponized: LIKELY
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploitation requires sending crafted IPC messages to the running application, which typically requires some level of access to the target system.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: 4.7.0 and later

Vendor Advisory: https://github.com/camunda/camunda-modeler/issues/2143

Restart Required: Yes

Instructions:

1. Download Camunda Modeler 4.7.0 or later from official sources. 2. Uninstall previous versions. 3. Install the updated version. 4. Restart the application.

🔧 Temporary Workarounds

Application Isolation

all

Run Camunda Modeler in a sandboxed or isolated environment with restricted file system access.

Network Segmentation

all

Restrict network access to systems running Camunda Modeler to prevent remote triggering of IPC messages.

🧯 If You Can't Patch

  • Run Camunda Modeler with minimal user privileges to limit file system access scope.
  • Implement application whitelisting to prevent execution of unauthorized scripts written via this vulnerability.

🔍 How to Verify

Check if Vulnerable:

Check Camunda Modeler version via Help → About menu. If version is 4.6.0 or earlier, the system is vulnerable.

Check Version:

On Windows: check installed programs list. On macOS/Linux: check application version in GUI or package manager.

Verify Fix Applied:

After updating, verify version is 4.7.0 or later in Help → About menu.

📡 Detection & Monitoring

Log Indicators:

  • Unusual file access patterns from Camunda Modeler process
  • IPC communication errors

Network Indicators:

  • Unexpected IPC traffic to Camunda Modeler process

SIEM Query:

Process: 'camunda-modeler' AND (FileOperation: 'Write' OR FileOperation: 'Read') WHERE Path NOT LIKE '%expected_directories%'

🔗 References

📤 Share & Export