CVE-2021-27459
📋 TL;DR
This vulnerability allows attackers to upload unvalidated files to Emerson Rosemount X-STREAM Gas Analyzer webservers, enabling remote code execution. Organizations using affected Emerson gas analyzer products are at risk. The vulnerability affects multiple product revisions.
💻 Affected Systems
- Emerson Rosemount X-STREAM Gas Analyzer
📦 What is this software?
X Stream Enhanced Xefd Firmware by Emerson
X Stream Enhanced Xegk Firmware by Emerson
X Stream Enhanced Xegp Firmware by Emerson
⚠️ Risk & Real-World Impact
Worst Case
Complete compromise of gas analyzer systems leading to manipulation of gas analysis data, disruption of industrial processes, or lateral movement to other industrial control systems.
Likely Case
Unauthorized access to gas analyzer systems, data manipulation, or service disruption affecting industrial operations.
If Mitigated
Limited impact with proper network segmentation and access controls preventing exploitation attempts.
🎯 Exploit Status
Unvalidated file upload vulnerability typically requires minimal technical skill to exploit once identified.
🛠️ Fix & Mitigation
✅ Official Fix
Patch Version: Contact Emerson for specific patched versions
Vendor Advisory: https://www.emerson.com/documents/automation/emerson-cyber-security-notification-update-emerson-rosemount-x-stream-gas-analyzers-en-95297.pdf
Restart Required: Yes
Instructions:
1. Contact Emerson for firmware updates. 2. Apply firmware updates following Emerson's instructions. 3. Restart affected devices. 4. Verify update completion.
🔧 Temporary Workarounds
Network Segmentation
allIsolate gas analyzers from untrusted networks using firewalls and VLANs
Access Control
allRestrict network access to gas analyzer webservers to authorized personnel only
🧯 If You Can't Patch
- Implement strict network segmentation to isolate affected devices
- Monitor for unusual file upload attempts to gas analyzer webservers
🔍 How to Verify
Check if Vulnerable:
Check device firmware version against Emerson's advisory and CISA ICSA-21-138-01
Check Version:
Check device web interface or Emerson diagnostic tools for firmware version
Verify Fix Applied:
Verify firmware version matches Emerson's patched versions and test file upload functionality
📡 Detection & Monitoring
Log Indicators:
- Unusual file upload attempts to gas analyzer webservers
- Unexpected process execution on gas analyzer systems
Network Indicators:
- HTTP POST requests with file uploads to gas analyzer IPs
- Unusual outbound connections from gas analygers
SIEM Query:
source_ip="gas_analyzer_ip" AND (http_method="POST" AND uri_contains="upload")