CVE-2021-22801

9.8 CRITICAL

📋 TL;DR

CVE-2021-22801 is a critical privilege management vulnerability in Schneider Electric's ConneXium Network Manager software that allows authenticated attackers to execute arbitrary commands through specially crafted event actions. This affects all versions of the software and could lead to complete system compromise. Organizations using this industrial network management software are at risk.

💻 Affected Systems

Products:
  • ConneXium Network Manager Software
Versions: All versions
Operating Systems: Windows-based systems running ConneXium Network Manager
Default Config Vulnerable: ⚠️ Yes
Notes: Requires authenticated access to the software's configuration interface to exploit the event actions feature.

📦 What is this software?

⚠️ Manual Verification Required

This CVE does not have specific version information in our database, so automatic vulnerability detection cannot determine if your system is affected.

Why? The CVE database entry doesn't specify which versions are vulnerable (no version ranges provided by the vendor/NVD).

🔒 Custom verification scripts are available for registered users. Sign up free to download automated test scripts.

Recommended Actions:
  1. Review the CVE details at NVD
  2. Check vendor security advisories for your specific version
  3. Test if the vulnerability is exploitable in your environment
  4. Consider updating to the latest version as a precaution

⚠️ Risk & Real-World Impact

🔴

Worst Case

Complete system takeover with administrative privileges, allowing attackers to disrupt industrial operations, steal sensitive data, or deploy ransomware across managed networks.

🟠

Likely Case

Unauthorized command execution leading to data exfiltration, network reconnaissance, or lateral movement within industrial control systems.

🟢

If Mitigated

Limited impact if proper network segmentation and access controls prevent exploitation attempts from reaching vulnerable systems.

🌐 Internet-Facing: HIGH
🏢 Internal Only: HIGH

🎯 Exploit Status

Public PoC: ✅ No
Weaponized: LIKELY
Unauthenticated Exploit: ✅ No
Complexity: LOW

Exploitation requires authenticated access but is straightforward once access is obtained. The vulnerability is in the event action configuration mechanism.

🛠️ Fix & Mitigation

✅ Official Fix

Patch Version: Contact Schneider Electric for specific patched versions

Vendor Advisory: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-02

Restart Required: Yes

Instructions:

1. Review Schneider Electric advisory SEVD-2021-285-02
2. Contact Schneider Electric support for patched software versions
3. Apply the provided patch following vendor instructions
4. Restart affected systems after patch application

🔧 Temporary Workarounds

Restrict Access to Management Interface

all

Limit network access to ConneXium Network Manager to only authorized administrators from trusted networks

Disable Unnecessary Event Actions

all

Review and disable any non-essential event action configurations in the software

🧯 If You Can't Patch

  • Implement strict network segmentation to isolate ConneXium systems from other critical infrastructure
  • Enforce multi-factor authentication and least privilege access controls for all administrative accounts

🔍 How to Verify

Check if Vulnerable:

Check if ConneXium Network Manager software is installed and review version against Schneider Electric's advisory

Check Version:

Check software version through ConneXium Network Manager interface or Windows Programs and Features

Verify Fix Applied:

Verify patch installation by checking software version and confirming with Schneider Electric support

📡 Detection & Monitoring

Log Indicators:

  • Unusual event action configurations
  • Multiple failed authentication attempts followed by successful login
  • Unexpected command execution events in system logs

Network Indicators:

  • Unusual outbound connections from ConneXium systems
  • Traffic patterns indicating command and control activity

SIEM Query:

source="ConneXium" AND (event="configuration_change" OR event="command_execution")